Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

Carleton University

$28,350.00

Electrical impedance tomography to monitor lung and heart function

EF 2010-11

Résumé
Electrical Impedance Tomography (EIT) uses a set of electrodes placed around the patient's body to apply current simulation and measure the resulting potentials, from which an image of the internal conductivity distribution is calculated. EIT is sensitive to physiological phenomena which affect the conductivity - it has been used to image the brain (to view perfusion changes due to epilepsy and stroke), the breast (to screen for cancerous regions), the abdomen (for gastric emptying) and thorax (to image the movement of blood and gas in the heart and lungs). My research focuses on thoracic applications, where EIT shows excellent promise as a tool to monitor the pattern of air and blood flow in infant and adult intensive care applications. These patients have lungs which are both inhomogeneous (needing an imaging technology to map the distribution of air and blood flow), and unstable (needing a monitoring technology to watch the patient's progress). The most important limitation to EIT is due to the electrodes, which move with breathing and posture changes. This research program will focus on addressing the electrode movement uncertainties to improve EIT for cardio-pulmonary imaging for patient monitoring in intensive care. Two avenues of research will be undertaken: 1) image reconstruction algorithms focusing on 3D image reconstruction using helper data from impedance plethysmography (IP) to correct for movement artefacts; and 2) Clinical and experimental validation in order to measure the accuracy of EIT, and to identify specific challenges for the algorithms. A successful outcome of this research will develop 1) novel equipment based on fusing data from EIT and IP sensors, 2) advanced image reconstruction algorithms to simultaneously image 3D electrode movements and conductivity distributions, and 3) clinical and experimental validations of these algorithms and equipment to clarify the accuracy and clinical potential of the technology.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
261592-2007
Name nom
Adler, Andrew
Department département
Systems and Computer Engineering
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2007
Award amount
28350
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
335
Committee name en
Electromag. & Electr. Systems (H)
Committee name fr
Électromagn. et syst. électr. (H)
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
4
Nb partie
5
Application title
Electrical impedance tomography to monitor lung and heart function
Keyword
NSERC
Application summary
Electrical Impedance Tomography (EIT) uses a set of electrodes placed around the patient's body to apply current simulation and measure the resulting potentials, from which an image of the internal conductivity distribution is calculated. EIT is sensitive to physiological phenomena which affect the conductivity - it has been used to image the brain (to view perfusion changes due to epilepsy and stroke), the breast (to screen for cancerous regions), the abdomen (for gastric emptying) and thorax (to image the movement of blood and gas in the heart and lungs). My research focuses on thoracic applications, where EIT shows excellent promise as a tool to monitor the pattern of air and blood flow in infant and adult intensive care applications. These patients have lungs which are both inhomogeneous (needing an imaging technology to map the distribution of air and blood flow), and unstable (needing a monitoring technology to watch the patient's progress). The most important limitation to EIT is due to the electrodes, which move with breathing and posture changes. This research program will focus on addressing the electrode movement uncertainties to improve EIT for cardio-pulmonary imaging for patient monitoring in intensive care. Two avenues of research will be undertaken: 1) image reconstruction algorithms focusing on 3D image reconstruction using helper data from impedance plethysmography (IP) to correct for movement artefacts; and 2) Clinical and experimental validation in order to measure the accuracy of EIT, and to identify specific challenges for the algorithms. A successful outcome of this research will develop 1) novel equipment based on fusing data from EIT and IP sensors, 2) advanced image reconstruction algorithms to simultaneously image 3D electrode movements and conductivity distributions, and 3) clinical and experimental validations of these algorithms and equipment to clarify the accuracy and clinical potential of the technology.