Grant: Research Tools and Instruments - Category 1 (<$150,000)
University of Alberta
$69,870.00
Renewal of a cryogenic refrigerator for supersolid researach
EF 2010-11
Résumé
This is a proposal to replace critical components of a cryogenic ""dilution refrigerator"", so that my laboratory can continue its research on supersolidity in helium. This new (and not yet understood) phase of matter exists only at temperatures within 200 mK (0.2 degree Kelvin) of absolute zero and, in pure crystals, only below 40 mK. The only way to reach such temperatures is with a dilution refrigerator. This is a complex apparatus in which a mixture of superfluid 4He and rare liquid 3He are circulated through a ""dilution stage"", whose critical components are a series of sintered silver nanopowder heat exchangers. The useful lifetime of such a fridge is limited by corrosion - the heat exchangers develop superleaks which are extremely difficult to locate and often impossible to repair without damaging them. The dilution stage of our current fridge is now 28 years old - far past its anticipated lifetime (it must be one of the oldest fridges still in operation). Not unexpectedly, during the past 2 years, our fridge developed leaks and other problems which required several months (and considerable luck) to repair. We propose to purchase a new dilution stage to replace the antique one on our current fridge. We designed this fridge in a modular fashion, to make such a replacement simple. The refrigeration capacity of the proposed dilution stage (e.g. minimum temperature of 12 mK) is similar to that of our current unit. Renewing our fridge with a new dilution stage (and some essential replacement thermometry components) will give us reliable cryogenic refrigeration for at least a decade, at less than 25% of the cost of a new dilution refrigerator. Without such renewal, our fridge will fail sooner or later - this would make our entire research program impossible.
Programme
Research Tools and Instruments - Category 1 (<$150,000)
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
389667-2010
Name nom
Beamish, John
Department département
Physics
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
69870
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1202
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Physical sciences
Area of application fr
Sciences physiques
Research subject code
3309
Research subject group en
Condensed matterphysics
Research subject group fr
Physique de la matière condensée
Research subject en
Low temperature physics
Research subject fr
Physique à basse température
Partie
1
Nb partie
1
Application title
Renewal of a cryogenic refrigerator for supersolid researach
Keyword
NSERC
Application summary
This is a proposal to replace critical components of a cryogenic ""dilution refrigerator"", so that my laboratory can continue its research on supersolidity in helium. This new (and not yet understood) phase of matter exists only at temperatures within 200 mK (0.2 degree Kelvin) of absolute zero and, in pure crystals, only below 40 mK. The only way to reach such temperatures is with a dilution refrigerator. This is a complex apparatus in which a mixture of superfluid 4He and rare liquid 3He are circulated through a ""dilution stage"", whose critical components are a series of sintered silver nanopowder heat exchangers. The useful lifetime of such a fridge is limited by corrosion - the heat exchangers develop superleaks which are extremely difficult to locate and often impossible to repair without damaging them. The dilution stage of our current fridge is now 28 years old - far past its anticipated lifetime (it must be one of the oldest fridges still in operation). Not unexpectedly, during the past 2 years, our fridge developed leaks and other problems which required several months (and considerable luck) to repair. We propose to purchase a new dilution stage to replace the antique one on our current fridge. We designed this fridge in a modular fashion, to make such a replacement simple. The refrigeration capacity of the proposed dilution stage (e.g. minimum temperature of 12 mK) is similar to that of our current unit. Renewing our fridge with a new dilution stage (and some essential replacement thermometry components) will give us reliable cryogenic refrigeration for at least a decade, at less than 25% of the cost of a new dilution refrigerator. Without such renewal, our fridge will fail sooner or later - this would make our entire research program impossible.