Grant: Engage Plus Grants Program
École de technologie supérieure
$12,500.00
Design of Silicon Carbide Surface-Micromachined Capacitive-based Transducers for Non-Destructive Testing Applications
EF 2017-18
Résumé
Ultrasonic transducers are seeing widespread use in low-intensity applications such as medical imaging,non-destructive testing and ranging, or in high-intensity ones like cleaning and liquid emulsification. Fordecades, piezoelectric transducers have been the workhorse in ultrasonics. However, micro-machinedcapacitive transducers are currently attracting significant interest. A unique advantage over their bulkpiezoelectric counterpart lies in their lower mechanical impedance, offering the potential for a betterimpedance match with low-density fluidic media such as air. The operation of such transducers is also muchless sensitive to temperature. Capacitive micromachined ultrasonic transducers (CMUTs) are usually integratedclosely with their interface electronic circuits forming complete stand-alone ultra-compact systems. This canallow ultrasonic systems to be integrated into handheld devices. The research group of Prof. Nabki hasdeveloped a novel Silicon Carbide CMUT, and demonstrated a proof of concept prototype showcasing thedevice's potential, and gaining the interest of Olympus Corporation, an international company with many R&Doperations in Canada. Olympus operates in industrial, medical and consumer markets, and specializes in optics,electronics and precision engineering, with products deployed in Canada and around the world. Notably,Olympus is a world-leading manufacturer of innovative non-destructive testing (NDT) instruments that areused in industrial and research applications. It has a large operation in Quebec City of about 400 people, whichhandles R & D and production.Throughout this Engage Plus project, Olympus is planning to expand its extensive testing plans of thepreviously fabricated CMUTs as part of a previous Engage project. The characterization will include flawdetection, beam profiling, and uniformity inspection. A second fabrication run will be performed to optimizethe CMUT's performance and durability. Finally, a demonstration kit will be developed for a smartphone thatincludes both the 5 MHz and 15 MHz CMUTs. This project will provide training for two Ph.D. students.
Programme
Engage Plus Grants Program
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
508361-2017
Name nom
Nabki, Frederic
Department département
Génie électrique
Organization id
53
Institution établissement
École de technologie supérieure
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
12500
Program id
EGP2
Program name en
Engage Plus Grants Program
Program name fr
Programme de subvention d'engagement partenarial Plus
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
2506
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electron devices
Research subject fr
Dispositifs électroniques
Partie
1
Nb partie
1
Application title
Design of Silicon Carbide Surface-Micromachined Capacitive-based Transducers for Non-Destructive Testing Applications
Keyword
NSERC
Application summary
Ultrasonic transducers are seeing widespread use in low-intensity applications such as medical imaging,non-destructive testing and ranging, or in high-intensity ones like cleaning and liquid emulsification. Fordecades, piezoelectric transducers have been the workhorse in ultrasonics. However, micro-machinedcapacitive transducers are currently attracting significant interest. A unique advantage over their bulkpiezoelectric counterpart lies in their lower mechanical impedance, offering the potential for a betterimpedance match with low-density fluidic media such as air. The operation of such transducers is also muchless sensitive to temperature. Capacitive micromachined ultrasonic transducers (CMUTs) are usually integratedclosely with their interface electronic circuits forming complete stand-alone ultra-compact systems. This canallow ultrasonic systems to be integrated into handheld devices. The research group of Prof. Nabki hasdeveloped a novel Silicon Carbide CMUT, and demonstrated a proof of concept prototype showcasing thedevice's potential, and gaining the interest of Olympus Corporation, an international company with many R&Doperations in Canada. Olympus operates in industrial, medical and consumer markets, and specializes in optics,electronics and precision engineering, with products deployed in Canada and around the world. Notably,Olympus is a world-leading manufacturer of innovative non-destructive testing (NDT) instruments that areused in industrial and research applications. It has a large operation in Quebec City of about 400 people, whichhandles R & D and production.Throughout this Engage Plus project, Olympus is planning to expand its extensive testing plans of thepreviously fabricated CMUTs as part of a previous Engage project. The characterization will include flawdetection, beam profiling, and uniformity inspection. A second fabrication run will be performed to optimizethe CMUT's performance and durability. Finally, a demonstration kit will be developed for a smartphone thatincludes both the 5 MHz and 15 MHz CMUTs. This project will provide training for two Ph.D. students.