Grant: Discovery Grants Program - Individual
University of Western Ontario
$32,000.00
Methods for optimal design of new detectors for advanced medical-imaging procedures
EF 2011-12
Résumé
Due to the health risks associated with exposure to x rays in medical diagnostic procedures, it is essential that x-ray detectors be designed to produce the best possible images while exposing the patient to the lowest acceptable levels of radiation. This balance between image quality and x-ray exposure on the detector is described by the ""detective quantum efficiency"" (DQE) of the detector and is particularly important in computed tomography (CT) imaging which is now responsible for half of all diagnostic medical exposures in North America. A new generation of detectors is currently under development that can measure the energy of x-ray photons for use in advanced imaging procedures including CT. While it is essential that these systems be designed to ensure low dose to patients, the tools required to develop optimal designs are primitive and inadequate for the task. As a consequence, we believe some detectors currently under have little chance of success, while others are not being developed to exploit the full potential of these advanced applications.
The full potential of these new detectors can only be achieved by developing the mathematical tools that relate physical design parameters and materials to the resulting image quality. We will build on previous contributions and the successes of Fourier-based linear systems to develop a cascaded-systems description of signal and noise as it pertains to photon-counting energy-discriminating detectors. We will introduce x-ray photon energy as an independent parameter in a multi-dimensional approach that will, for the first time, accommodate spatial correlations in image signals that result from energy-dependent x-ray interactions. It is these correlations that degrade the DQE of imaging systems, and are ultimately responsible for poor image quality requiring the use of higher radiation exposures to patients. Results from this research will provide the first means to develop optimal detectors for these advanced applications, and to assess and verify their potential to produce high-quality images while maintaining low levels of x-ray exposure to patients.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
386330-2010
Name nom
Cunningham, Ian
Department département
Medical Imaging
Organization id
36
Institution établissement
University of Western Ontario
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2010
Award amount
32000
Program id
RGPIN
Program nane en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
2
Nb partie
5
Application title
Methods for optimal design of new detectors for advanced medical-imaging procedures
Keyword
NSERC
Application summary
Due to the health risks associated with exposure to x rays in medical diagnostic procedures, it is essential that x-ray detectors be designed to produce the best possible images while exposing the patient to the lowest acceptable levels of radiation. This balance between image quality and x-ray exposure on the detector is described by the ""detective quantum efficiency"" (DQE) of the detector and is particularly important in computed tomography (CT) imaging which is now responsible for half of all diagnostic medical exposures in North America. A new generation of detectors is currently under development that can measure the energy of x-ray photons for use in advanced imaging procedures including CT. While it is essential that these systems be designed to ensure low dose to patients, the tools required to develop optimal designs are primitive and inadequate for the task. As a consequence, we believe some detectors currently under have little chance of success, while others are not being developed to exploit the full potential of these advanced applications.
The full potential of these new detectors can only be achieved by developing the mathematical tools that relate physical design parameters and materials to the resulting image quality. We will build on previous contributions and the successes of Fourier-based linear systems to develop a cascaded-systems description of signal and noise as it pertains to photon-counting energy-discriminating detectors. We will introduce x-ray photon energy as an independent parameter in a multi-dimensional approach that will, for the first time, accommodate spatial correlations in image signals that result from energy-dependent x-ray interactions. It is these correlations that degrade the DQE of imaging systems, and are ultimately responsible for poor image quality requiring the use of higher radiation exposures to patients. Results from this research will provide the first means to develop optimal detectors for these advanced applications, and to assess and verify their potential to produce high-quality images while maintaining low levels of x-ray exposure to patients.