Grant: Collaborative Health Research Projects
McGill University
$60,316.00
IMPLANTABLE MICRO-DEVICE to MONITOR MUSCLE COMPARTMENT PRESSURE in TRAUMA VICTIMS
EF 2016-17
Résumé
In human limbs the muscles are bundled into compartments surrounded by inelastic tissue called fascia. High energy impactto muscles, such as that sustained during an accident, results in swelling of the damaged tissue. This raises the tissuepressure and results in the condition called Acute Compartment Syndrome (ACS). The confining fascia must be cut torelease pressure once it rises to a critical level or the patient will experience severe intractable pain and disability as a resultof permanent muscle damage. There is no existing technology capable of measuring muscle compartment pressureaccurately and on a continuous basis. The goal of this project is to develop a simple, miniature, wireless device that can beused by first responders in the field or in an emergency department to measure pressure, oxygen and temperaturefluctuations in the muscle compartments of patients at risk of ACS. The proposed device measuring 4 mm x 23 mm will bedelivered to the compartment with a modified syringe and will have a tail that protrudes from the skin to facilitate removal 48hours post injury. The sensor will undergo pre-clinical assessment in established models of compartment syndrome,including live animal and human cadaveric models. The intellectual property for the device is protected by an agreement withMcGill University and a working agreement has been signed with the technology user, Sharp Microsystems. The medicaldevice lobby group MEDEC has also been engaged for eventual dispersal. We believe this device will revolutionize themanagement of trauma victims in every hospital throughout the world and minimize the devastating outcomes for patientsdiagnosed with ACS.
Programme
Collaborative Health Research Projects
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
462278-2014
Name nom
Harvey, Edward
Department département
Surgery
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2014
Award amount
60316
Program id
CHRPJ
Program name en
Collaborative Health Research Projects
Program name fr
Projets de recherche concertée sur la santé
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
360
Committee name en
Collaborative Health Research Projects Selection Panel
Committee name fr
Comité de sélection de projets de recherche concertée sur la santé
Area of application code
9999
Area of application group en
Not available
Area of application group fr
Non disponible
Area of application en
Not available
Area of application fr
Non disponible
Research subject code
9999
Research subject group en
Not available
Research subject group fr
Non disponible
Research subject en
Not available
Research subject fr
Non disponible
Partie
3
Nb partie
3
Application title
IMPLANTABLE MICRO-DEVICE to MONITOR MUSCLE COMPARTMENT PRESSURE in TRAUMA VICTIMS
Keyword
NSERC
Application summary
In human limbs the muscles are bundled into compartments surrounded by inelastic tissue called fascia. High energy impactto muscles, such as that sustained during an accident, results in swelling of the damaged tissue. This raises the tissuepressure and results in the condition called Acute Compartment Syndrome (ACS). The confining fascia must be cut torelease pressure once it rises to a critical level or the patient will experience severe intractable pain and disability as a resultof permanent muscle damage. There is no existing technology capable of measuring muscle compartment pressureaccurately and on a continuous basis. The goal of this project is to develop a simple, miniature, wireless device that can beused by first responders in the field or in an emergency department to measure pressure, oxygen and temperaturefluctuations in the muscle compartments of patients at risk of ACS. The proposed device measuring 4 mm x 23 mm will bedelivered to the compartment with a modified syringe and will have a tail that protrudes from the skin to facilitate removal 48hours post injury. The sensor will undergo pre-clinical assessment in established models of compartment syndrome,including live animal and human cadaveric models. The intellectual property for the device is protected by an agreement withMcGill University and a working agreement has been signed with the technology user, Sharp Microsystems. The medicaldevice lobby group MEDEC has also been engaged for eventual dispersal. We believe this device will revolutionize themanagement of trauma victims in every hospital throughout the world and minimize the devastating outcomes for patientsdiagnosed with ACS.