Grant: Engage Grants Program
Ryerson University
$24,935.00
A real-time ultrasound image processing technique for computer-assisted and image-guided interventional technologies
EF 2013-14
Résumé
Image-guided medical interventions and surgeries rely on one or more imaging feedback to monitor the treatment and to guide an interventionist or surgeon in placing and operating a medical tool or probe with respect to a target tissue. Conventional imaging techniques such as X-ray, CT (computed tomography) scan, and MRI (magnetic resonance imaging) impose several shortcomings for many image-guided medical operations. For instance, X-ray and CT scans are harmful to the human body in large doses, while MRI and US (ultrasound) are known to be safe. On the other hand, MRI has prohibitively slow imaging speeds, requires special facilities, incurs high costs, and cannot be moved into the operating room. In contrast, US imaging is relatively cheap, portable, and operates in real-time (24-30 fps), making it the preferred imaging technologyamong surgeons/clinicians. Despite its advantages, there are a number of difficulties associated with using US imaging in medical applications. It has high noise, poor contrast and shape definition, and high imaging artifacts that can distort the appearance of tissues and intervention instruments. Medmectron Inc. is a company conducting R&D on image-guided interventional and surgical tools. Medmectron is in immediate need to integrate automated target tissue segmentation and tracking using US images for its navigation platforms used in robotic cardiac and robotic prostate intervention systems. This will significantly improve their products quality and productivity. The objective of the proposed engage program is to develop a robust and real-time US image processing method for targeted tissue segmentation, image registration, and tracking using US images which, in addition to the aforementioned applications, can be useful for many other medical/diagnostic applications. The proposed project will improve accuracy, and robustness of US imaging techniques and US-based interventions for many diagnostic and therapeutic procedures. This will be translated into more accurate, safer and more cost-effective treatments, reducing burden on Health Care system.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
453815-2013
Name nom
Tavakkoli, Jahan
Department département
Physics
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
24935
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
1
Nb partie
1
Application title
A real-time ultrasound image processing technique for computer-assisted and image-guided interventional technologies
Keyword
NSERC
Application summary
Image-guided medical interventions and surgeries rely on one or more imaging feedback to monitor the treatment and to guide an interventionist or surgeon in placing and operating a medical tool or probe with respect to a target tissue. Conventional imaging techniques such as X-ray, CT (computed tomography) scan, and MRI (magnetic resonance imaging) impose several shortcomings for many image-guided medical operations. For instance, X-ray and CT scans are harmful to the human body in large doses, while MRI and US (ultrasound) are known to be safe. On the other hand, MRI has prohibitively slow imaging speeds, requires special facilities, incurs high costs, and cannot be moved into the operating room. In contrast, US imaging is relatively cheap, portable, and operates in real-time (24-30 fps), making it the preferred imaging technologyamong surgeons/clinicians. Despite its advantages, there are a number of difficulties associated with using US imaging in medical applications. It has high noise, poor contrast and shape definition, and high imaging artifacts that can distort the appearance of tissues and intervention instruments. Medmectron Inc. is a company conducting R&D on image-guided interventional and surgical tools. Medmectron is in immediate need to integrate automated target tissue segmentation and tracking using US images for its navigation platforms used in robotic cardiac and robotic prostate intervention systems. This will significantly improve their products quality and productivity. The objective of the proposed engage program is to develop a robust and real-time US image processing method for targeted tissue segmentation, image registration, and tracking using US images which, in addition to the aforementioned applications, can be useful for many other medical/diagnostic applications. The proposed project will improve accuracy, and robustness of US imaging techniques and US-based interventions for many diagnostic and therapeutic procedures. This will be translated into more accurate, safer and more cost-effective treatments, reducing burden on Health Care system.