Grant: Engage Grants Program
McGill University
$25,000.00
Development of a Finite Element Model for the Optimization of a FFR Catheter
EF 2010-11
Résumé
According to the American Heart Association cardiovascular disease affects 36.9% of the population, with
approximately 30% of patients suffering from coronary artery disease. Acute Coronary Syndrome, associated
with myocardial infarction, requires fast diagnosis and revascularization. Traditionally clinicians have chosen
treatment methods by estimating the amount of flow going through the diseased coronary artery. Although
several methods exist, catheter based pressure measurements are widespread among clinicians. Fractional flow
reserve (FFR) is an index of the physiological significance of a coronary stenosis and is a measure of the
maximal blood flow in a diseased artery to normal maximal flow. It is measured by comparing the pressure
before and after the diseased arterial section, and thus indirectly estimating the loss of myocardial perfusion.
Opsens has developed a FFR technology based on a photonic principle instead of the piezoelectric principle of
the conventional technologies. This new photonic based technology has the potential to be more sensitive than
current piezoelectric based technologies. Our partner is in the stage of evaluating how FFR measurements are
affected by the obstructive effects associated with their new catheter design and the anatomical location of the
sensor. We propose developing a computational fluid dynamics model to study the hemodynamic disturbances
(pressure drop) associated with the presence of the Opsens catheter in the stenosis and optimize its design in
order to maximize its sensitivity and specificity.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
396177-2010
Name nom
Mongrain, Rosaire
Department département
Mechanical Engineering
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
1
Nb partie
1
Application title
Development of a Finite Element Model for the Optimization of a FFR Catheter
Keyword
NSERC
Application summary
According to the American Heart Association cardiovascular disease affects 36.9% of the population, with
approximately 30% of patients suffering from coronary artery disease. Acute Coronary Syndrome, associated
with myocardial infarction, requires fast diagnosis and revascularization. Traditionally clinicians have chosen
treatment methods by estimating the amount of flow going through the diseased coronary artery. Although
several methods exist, catheter based pressure measurements are widespread among clinicians. Fractional flow
reserve (FFR) is an index of the physiological significance of a coronary stenosis and is a measure of the
maximal blood flow in a diseased artery to normal maximal flow. It is measured by comparing the pressure
before and after the diseased arterial section, and thus indirectly estimating the loss of myocardial perfusion.
Opsens has developed a FFR technology based on a photonic principle instead of the piezoelectric principle of
the conventional technologies. This new photonic based technology has the potential to be more sensitive than
current piezoelectric based technologies. Our partner is in the stage of evaluating how FFR measurements are
affected by the obstructive effects associated with their new catheter design and the anatomical location of the
sensor. We propose developing a computational fluid dynamics model to study the hemodynamic disturbances
(pressure drop) associated with the presence of the Opsens catheter in the stenosis and optimize its design in
order to maximize its sensitivity and specificity.