Grant: Research Tools and Instruments
Wilfrid Laurier University
$52,470.00
Automated critical point dry instrumentation for scanning electron microscopy applications
EF 2016-17
Résumé
Scanning electron microscopy (SEM) is currently the standard imaging technique used to generate surface morphological data. The high resolution provided by SEM reveals nano-scale features that are inaccessible to conventional microscopy, while its superior range of focus also allows examination at low magnifications with better results than stereomicroscopy. In classical SEM, the observation takes place in vacuum conditions. This requires the prior removal of water from samples, which is typical for biological specimens. However, direct air dehydration produces cell/tissue deformations that render the samples unsuitable for observation. To circumvent this problem, samples must be either chemically dried or dehydrated using a critical point dry (CPD) instrument. In the former case, the water in cells is substituted with a chemical solvent, which is subsequently evaporated. In the latter case, a CPD instrument replaces the internal water with liquid carbon dioxide (LCO2) at a certain combination of temperature and pressure. The chemical drying process is slow and toxic, and can create artifacts at higher magnifications. Using a CPD instrument is much faster, more accurate, and environmentally friendly.
Funds are requested to purchase an automated, programmable CPD Tousimis Autosamdri 931, which will primarily benefit my NSERC Discovery research program on the diversity and evolution of parasitic plants. Overall, this research program is part of the ongoing global effort to catalog life on Earth and understand its natural history and evolution. Its main objective is to reconstruct the evolutionary relationships among the parasitic Cuscuta (dodder) species and revise their taxonomy using morphological, molecular, and cytological data. From a practical point of view, this research program facilitates better identification and management of pest and native Cuscuta species in Canada and worldwide. The CPD instrument will significantly increase research productivity and allow my program to reach its full potential both in terms of efficiency and reduced labor cost/time. The CPD instrument will also support the SEM research of other faculty members at Laurier because no such instrument exists in the university.
Programme
Research Tools and Instruments
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RTI-2017-00424
Name nom
Costea, Mihai
Department département
Biology - Biology
Organization id
35
Institution établissement
Wilfrid Laurier University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2017
Award amount
52470
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1603
Committee name en
Environmental Sciences (RTI)
Committee name fr
Sciences environnementales (OIR)
Area of application code
1209
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Agriculture
Area of application fr
Agriculture
Research subject code
4709
Research subject group en
Evolution and ecology
Research subject group fr
Évolution et écologie
Research subject en
Taxonomy, systematics and phylogenetics
Research subject fr
Taxonomie, systématique et phylogénétique
Partie
1
Nb partie
1
Application title
Automated critical point dry instrumentation for scanning electron microscopy applications
Keyword
NSERC
Application summary
Scanning electron microscopy (SEM) is currently the standard imaging technique used to generate surface morphological data. The high resolution provided by SEM reveals nano-scale features that are inaccessible to conventional microscopy, while its superior range of focus also allows examination at low magnifications with better results than stereomicroscopy. In classical SEM, the observation takes place in vacuum conditions. This requires the prior removal of water from samples, which is typical for biological specimens. However, direct air dehydration produces cell/tissue deformations that render the samples unsuitable for observation. To circumvent this problem, samples must be either chemically dried or dehydrated using a critical point dry (CPD) instrument. In the former case, the water in cells is substituted with a chemical solvent, which is subsequently evaporated. In the latter case, a CPD instrument replaces the internal water with liquid carbon dioxide (LCO2) at a certain combination of temperature and pressure. The chemical drying process is slow and toxic, and can create artifacts at higher magnifications. Using a CPD instrument is much faster, more accurate, and environmentally friendly.
Funds are requested to purchase an automated, programmable CPD Tousimis Autosamdri 931, which will primarily benefit my NSERC Discovery research program on the diversity and evolution of parasitic plants. Overall, this research program is part of the ongoing global effort to catalog life on Earth and understand its natural history and evolution. Its main objective is to reconstruct the evolutionary relationships among the parasitic Cuscuta (dodder) species and revise their taxonomy using morphological, molecular, and cytological data. From a practical point of view, this research program facilitates better identification and management of pest and native Cuscuta species in Canada and worldwide. The CPD instrument will significantly increase research productivity and allow my program to reach its full potential both in terms of efficiency and reduced labor cost/time. The CPD instrument will also support the SEM research of other faculty members at Laurier because no such instrument exists in the university.