Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of British Columbia

$43,000.00

Automated analysis of high dimensional flow cytometry data

EF 2013-14

Résumé
The recent increase in the amount of data generated by flow cytometry (FCM) poses unique informatics and statistical challenges, and it is widely recognized that one basic challenge for FCM is to simplify the extraction of data and statistical information. Traditionally, the majority of FCM experiments have been analyzed visually, through time-consuming and subjective serial inspection of one or two dimensions at a time, of up to 17 dimensional data. While commercially available analysis tools are designed to facilitate this process, such visual procedures necessarily neglect the higher dimensionality of the data. Furthermore, the subjective character of visual analysis is a major obstacle to the automation and reproducibility of research. In contrast to 2D visual analysis, a multivariate statistical analysis can mine the full set of markers simultaneously. In this research program we will develop novel and extend existing statistical tools to assist in the analysis of high throughput, high dimensional flow cytometry data. We will continue our tool and algorithm development with a focus on semi-supervised clustering methods for FCM data and integrating analysis across multiple sample aliquots, two areas that have not yet been adequately addressed within the community. In the longer term we will develop new approaches for automatically identifying what are the significant differences between sample groups. We will work with basic researchers to then apply these methods to several datasets to both improve our methods through interactions with biologists, and to answer several biological questions. An important collaboration will be with the International Mouse Phenotyping Consortium, which is knocking out each gene in an attempt to understand its function. The development of these methodologies will improve the robustness of results over the manual analysis for all the areas where this technology is employed. This will open the possibility to use FCM as a non-hypothesis driven technology, making plausible the discovery of unforeseen relationships and discoveries that would not have been otherwise identified.
Programme
Discovery Grants Program - Individual
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
327707-2013
Name nom
Brinkman, Ryan
Department département
Medical Genetics
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
43000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1501
Committee name en
Genes, Cells and Molecules
Committee name fr
Gènes, cellules et molécules
Area of application code
801
Area of application group en
Information and communication services
Area of application group fr
Services d'information et de télécommunications
Area of application en
Computer software
Area of application fr
Logiciel
Research subject code
9000
Research subject group en
Medical sciences
Research subject group fr
Sciences médicales
Research subject en
Medical sciences
Research subject fr
Sciences médicales
Partie
1
Nb partie
5
Application title
Automated analysis of high dimensional flow cytometry data
Keyword
NSERC
Application summary
The recent increase in the amount of data generated by flow cytometry (FCM) poses unique informatics and statistical challenges, and it is widely recognized that one basic challenge for FCM is to simplify the extraction of data and statistical information. Traditionally, the majority of FCM experiments have been analyzed visually, through time-consuming and subjective serial inspection of one or two dimensions at a time, of up to 17 dimensional data. While commercially available analysis tools are designed to facilitate this process, such visual procedures necessarily neglect the higher dimensionality of the data. Furthermore, the subjective character of visual analysis is a major obstacle to the automation and reproducibility of research. In contrast to 2D visual analysis, a multivariate statistical analysis can mine the full set of markers simultaneously. In this research program we will develop novel and extend existing statistical tools to assist in the analysis of high throughput, high dimensional flow cytometry data. We will continue our tool and algorithm development with a focus on semi-supervised clustering methods for FCM data and integrating analysis across multiple sample aliquots, two areas that have not yet been adequately addressed within the community. In the longer term we will develop new approaches for automatically identifying what are the significant differences between sample groups. We will work with basic researchers to then apply these methods to several datasets to both improve our methods through interactions with biologists, and to answer several biological questions. An important collaboration will be with the International Mouse Phenotyping Consortium, which is knocking out each gene in an attempt to understand its function. The development of these methodologies will improve the robustness of results over the manual analysis for all the areas where this technology is employed. This will open the possibility to use FCM as a non-hypothesis driven technology, making plausible the discovery of unforeseen relationships and discoveries that would not have been otherwise identified.