Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of Western Ontario

$37,150.00

Approaches for hyperpolarized noble gas magnetic resonance imaging of rodent lungs

EF 2011-12

Résumé
Hyperpolarized Noble Gases (HNG), specifically helium-3 and xenon-129, have significantly expanded the capability of Magnetic Resonance (MR) imaging in recent years, most notably for visualizing human lung anatomy and function. HNG MR imaging offers several important advantages: (i) safety, (ii) high spatial and temporal resolution and (iii) functional information. A further novel feature of HNG is that the optimal image quality is achieved at magnetic field strengths substantially lower than most conventional MR imaging systems. Low field can reduce MR complexity and costs, allow new ""open magnet"" geometries for reduced claustrophobia and permit exploration of the effects of posture on lung physiology. Furthermore, the substantially increased transverse relaxation times available at low fields provides a unique opportunity to measure fundamental long-range gas diffusion and rapid oxygenation changes in the lung not possible at high fields. The objectives of the proposed research are: i) to optimize a low field MR imaging system; ii) to develop mathematical models of the relationships between measured low field HNG parameters and the anatomical and physiological properties of the lung (surface area, airway sizes, inflammation and oxygenation); iii) to develop and validate new low field HNG MR imaging methods sensitive to rodent models of lung disease. The proposed research will take place at the low field hyperpolarized MR imaging laboratory at the University of Western Ontario (Robarts Research Institute) established in part with previous NSERC Discovery funding. The research plan will bring together the expertise of the low field hyperpolarized MR imaging laboratory in the production and delivery of HNG in vivo, hardware and software development and mathematical modeling with the expertise of the Physics Department at UWO in pulsed-field MR hardware and the expertise of the UWO School of Medicine and Dentistry in the development of experimental models of lung disease in rodents. The significance of the proposed research is high as low field HNG MRI is entirely novel and therefore will provide significant opportunities for knowledge generation, both basic and applied.
Programme
Discovery Grants Program - Individual
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
217015-2008
Name nom
Santyr, Giles
Department département
Medical Biophysics
Organization id
36
Institution établissement
University of Western Ontario
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2008
Award amount
37150
Program id
RGPIN
Program nane en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
29
Committee name en
General Physics
Committee name fr
Physique générale
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Biological and Medical Physics
Research subject fr
Physique biologique et médicale
Partie
4
Nb partie
5
Application title
Approaches for hyperpolarized noble gas magnetic resonance imaging of rodent lungs
Keyword
NSERC
Application summary
Hyperpolarized Noble Gases (HNG), specifically helium-3 and xenon-129, have significantly expanded the capability of Magnetic Resonance (MR) imaging in recent years, most notably for visualizing human lung anatomy and function. HNG MR imaging offers several important advantages: (i) safety, (ii) high spatial and temporal resolution and (iii) functional information. A further novel feature of HNG is that the optimal image quality is achieved at magnetic field strengths substantially lower than most conventional MR imaging systems. Low field can reduce MR complexity and costs, allow new ""open magnet"" geometries for reduced claustrophobia and permit exploration of the effects of posture on lung physiology. Furthermore, the substantially increased transverse relaxation times available at low fields provides a unique opportunity to measure fundamental long-range gas diffusion and rapid oxygenation changes in the lung not possible at high fields. The objectives of the proposed research are: i) to optimize a low field MR imaging system; ii) to develop mathematical models of the relationships between measured low field HNG parameters and the anatomical and physiological properties of the lung (surface area, airway sizes, inflammation and oxygenation); iii) to develop and validate new low field HNG MR imaging methods sensitive to rodent models of lung disease. The proposed research will take place at the low field hyperpolarized MR imaging laboratory at the University of Western Ontario (Robarts Research Institute) established in part with previous NSERC Discovery funding. The research plan will bring together the expertise of the low field hyperpolarized MR imaging laboratory in the production and delivery of HNG in vivo, hardware and software development and mathematical modeling with the expertise of the Physics Department at UWO in pulsed-field MR hardware and the expertise of the UWO School of Medicine and Dentistry in the development of experimental models of lung disease in rodents. The significance of the proposed research is high as low field HNG MRI is entirely novel and therefore will provide significant opportunities for knowledge generation, both basic and applied.