Grant: Discovery Grants Program - Individual
Carleton University
$22,000.00
Adaptive Integrated Circuits for Wearable Technology
EF 2016-17
Résumé
The proposed research area is ""wearable technologies"" and the focus is on advanced hardware implementation of circuits that will enable the upcoming fourth generation of wearable technologies.
Just as the smart phone replaced the personal computer as the interface technology of choice for a large segment of the world's population, wearable technologies are now supplanting the smart phone. While the smart phone has become nearly ubiquitous across an enormous segment of the world's population, wearable technologies are spurring an even greater level of connectedness between humans and technology and information stores. There is an ongoing and rapidly accelerating move towards wearable technologies as the preferred interface modality.
Early first-generation wearable technologies only displayed information. Second-generation wearable technologies also collected information. Third-generation wearable technologies apply machine intelligence and pattern recognition on collected information in order to provide actionable recommendations to the wearable technology user. The upcoming fourth-generation of wearable technology collects fine-grained rich data from a vast population of users in order to mine the data for trends and signature features that enable the system to predict future events. The amount of interface and processing technology present in a fourth generation wearable technology implementation eclipses that of even a third-generation wearable technology device implementation by a very wide margin.
The proposed research will produce circuitry components that are of critical importance for fourth generation wearable technology implementations where there is a simultaneous drive towards decreased size, lower power requirements, higher performance, and lower cost. These desirable features are generally achieved by process technology scaling, for example moving to smaller feature sizes in CMOS technologies, but doing so creates a host of problems related to circuit performance.
The circuit performance required for fourth generation wearable technology will be achieved through innovative integrated signal measurement circuits, analog signal multiplexing circuits, signal processing circuits, and feedback circuits that will adjust the operating point and configuration of each primary circuit that requires adaptation. Such circuits are essential for upcoming wearable technology implementations that have demanding performance requirements on par with current medical grade equipment, while targeting the general consumer at an order of magnitude lower cost and operating complexity.
Integral to the proposed research is training highly qualified personnel in the areas of microelectronics, wireless and wireline communication systems, and sensor technologies focused on bio-sensing and environmental monitoring.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RGPIN-2015-04777
Name nom
MacEachern, Leonard
Department département
Electronics - Electronics
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2015
Award amount
22000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
1207
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Information, computer and communication technologies
Area of application fr
Technologie de l'information, des ordinateurs et des réseaux de communications
Research subject code
2506
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electron devices
Research subject fr
Dispositifs électroniques
Partie
2
Nb partie
5
Application title
Adaptive Integrated Circuits for Wearable Technology
Keyword
NSERC
Application summary
The proposed research area is ""wearable technologies"" and the focus is on advanced hardware implementation of circuits that will enable the upcoming fourth generation of wearable technologies.
Just as the smart phone replaced the personal computer as the interface technology of choice for a large segment of the world's population, wearable technologies are now supplanting the smart phone. While the smart phone has become nearly ubiquitous across an enormous segment of the world's population, wearable technologies are spurring an even greater level of connectedness between humans and technology and information stores. There is an ongoing and rapidly accelerating move towards wearable technologies as the preferred interface modality.
Early first-generation wearable technologies only displayed information. Second-generation wearable technologies also collected information. Third-generation wearable technologies apply machine intelligence and pattern recognition on collected information in order to provide actionable recommendations to the wearable technology user. The upcoming fourth-generation of wearable technology collects fine-grained rich data from a vast population of users in order to mine the data for trends and signature features that enable the system to predict future events. The amount of interface and processing technology present in a fourth generation wearable technology implementation eclipses that of even a third-generation wearable technology device implementation by a very wide margin.
The proposed research will produce circuitry components that are of critical importance for fourth generation wearable technology implementations where there is a simultaneous drive towards decreased size, lower power requirements, higher performance, and lower cost. These desirable features are generally achieved by process technology scaling, for example moving to smaller feature sizes in CMOS technologies, but doing so creates a host of problems related to circuit performance.
The circuit performance required for fourth generation wearable technology will be achieved through innovative integrated signal measurement circuits, analog signal multiplexing circuits, signal processing circuits, and feedback circuits that will adjust the operating point and configuration of each primary circuit that requires adaptation. Such circuits are essential for upcoming wearable technology implementations that have demanding performance requirements on par with current medical grade equipment, while targeting the general consumer at an order of magnitude lower cost and operating complexity.
Integral to the proposed research is training highly qualified personnel in the areas of microelectronics, wireless and wireline communication systems, and sensor technologies focused on bio-sensing and environmental monitoring.