Grant: Collaborative Research and Development Grants
University of Waterloo
$42,177.00
Reliable ultrasonic non-destructive testing and asset management of utility wood poles
EF 2012-13
Résumé
An assessment of the condition of wood poles is a critical step in the development of successful and safe maintenance programmes. Electricity companies consider wood poles to be an asset with high value and high risk of failure. Presently, the condition assessment of wood poles is based on visual inspection and sounding tests using a hammer to detect hollow sections. These inspection tests are subjective; whereas, intrusive tests are expensive and intrusive. Utility owners urgently need a reliable technique to perform cost-effective maintenance and rehabilitation programmes of wood poles. This project is specifically aimed at developing a new methodology for the condition assessment of wood poles. A robust experimental and analytical methodology is proposed; which is based not only on the latest ultrasonic testing methods but also on the latest probabilistic data analysis techniques. Ultrasonic tests are used to measure the residual strength of individual wood poles in-situ; whereas statistical methods are used to assess the reliability of the wood-pole infrastructure as a whole. In ultrasonic testing, changes in medium properties are evaluated from a single point of information out of thousands that are actually recorded. Because the response of ultrasonic transducers is not directly proportional to the actual motion of the medium. A state-of-the-art nano-laser system (recently purchased, RTI grant, 2011) will be used to measure the actual input excitations and medium responses generated by ultrasonic transducers in wood poles. From the actual input and output responses, the internal condition of a wood pole will be evaluated. The proposed project will reduce the costs of the Canadian power generation industry by introducing cost-effective maintenance and rehabilitation operations. The ultrasonic data set generated by an array of ultrasonic transducers attached to a calibrated belt will be analyzed using advanced signal processing techniques to extract the main features from the waveforms; these features will then be used to train a set of statistical classification algorithms. From the statistical classification, an image of the decayed areas in a wood pole will be displayed and the remaining strength evaluated.
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
418931-2011
Name nom
Cascante, Giovanni
Department département
Civil & Environmental Engineering
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2011
Award amount
42177
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
2
Nb partie
2
Application title
Reliable ultrasonic non-destructive testing and asset management of utility wood poles
Keyword
NSERC
Application summary
An assessment of the condition of wood poles is a critical step in the development of successful and safe maintenance programmes. Electricity companies consider wood poles to be an asset with high value and high risk of failure. Presently, the condition assessment of wood poles is based on visual inspection and sounding tests using a hammer to detect hollow sections. These inspection tests are subjective; whereas, intrusive tests are expensive and intrusive. Utility owners urgently need a reliable technique to perform cost-effective maintenance and rehabilitation programmes of wood poles. This project is specifically aimed at developing a new methodology for the condition assessment of wood poles. A robust experimental and analytical methodology is proposed; which is based not only on the latest ultrasonic testing methods but also on the latest probabilistic data analysis techniques. Ultrasonic tests are used to measure the residual strength of individual wood poles in-situ; whereas statistical methods are used to assess the reliability of the wood-pole infrastructure as a whole. In ultrasonic testing, changes in medium properties are evaluated from a single point of information out of thousands that are actually recorded. Because the response of ultrasonic transducers is not directly proportional to the actual motion of the medium. A state-of-the-art nano-laser system (recently purchased, RTI grant, 2011) will be used to measure the actual input excitations and medium responses generated by ultrasonic transducers in wood poles. From the actual input and output responses, the internal condition of a wood pole will be evaluated. The proposed project will reduce the costs of the Canadian power generation industry by introducing cost-effective maintenance and rehabilitation operations. The ultrasonic data set generated by an array of ultrasonic transducers attached to a calibrated belt will be analyzed using advanced signal processing techniques to extract the main features from the waveforms; these features will then be used to train a set of statistical classification algorithms. From the statistical classification, an image of the decayed areas in a wood pole will be displayed and the remaining strength evaluated.