Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

McMaster University

$23,000.00

A simultaneous PET/MR system for whole body imaging

EF 2013-14

Résumé
We plan to develop a high performance whole body Positron Emission Tomography (PET) system that can be inserted into an Magnetic Resonance (MR) system for simultaneous PET/MR imaging without performance degradation for both systems. The PET system will be configured as a ring of approximately 52 cm inner diameter and 20 cm axial dimension that fits within a whole body 3T MR system of 60 cm diameter bore. The NSERC financial support will help us build the necessary infrastructures and a 1/3rd of the full system for proof-of-principle. There are significant technology differences between the proposed whole body PET/MR and previous designs. First, the PET detectors are based upon silicon photomultipliers (SiPMs) and exhibit superior performances. Second, an electro-optically coupling scheme using laser diodes is deployed to minimize potential interferences between two systems. If successful, this proposal will lead to a truly simultaneous PET/MR hybrid system for whole body imaging. In addition to the benefits of PET/CT, the multiplicity of MR's anatomical information and PET's functional/molecular information will enable new paradigms for diseases diagnosis, prognosis and treatment in cancer screening/staging, cardiac imaging, therapy monitoring, and characterization of Alzheimer's disease. The proposed system will help physicians to detect diseases in the early stage with increase specificity and manage treatment plans more effectively. We believe that a simultaneous PET/MR system could ultimately make great impacts for advancing healthcare technology and improving quality of life in Canada. Economic benefits from commercialization and technology licensing through collaboration with industry partners are also expected.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
402124-2012
Name nom
Peng, Hao
Department département
Medical Physics & Applied Radiation Sciences
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2012
Award amount
23000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
2
Nb partie
5
Application title
A simultaneous PET/MR system for whole body imaging
Keyword
NSERC
Application summary
We plan to develop a high performance whole body Positron Emission Tomography (PET) system that can be inserted into an Magnetic Resonance (MR) system for simultaneous PET/MR imaging without performance degradation for both systems. The PET system will be configured as a ring of approximately 52 cm inner diameter and 20 cm axial dimension that fits within a whole body 3T MR system of 60 cm diameter bore. The NSERC financial support will help us build the necessary infrastructures and a 1/3rd of the full system for proof-of-principle. There are significant technology differences between the proposed whole body PET/MR and previous designs. First, the PET detectors are based upon silicon photomultipliers (SiPMs) and exhibit superior performances. Second, an electro-optically coupling scheme using laser diodes is deployed to minimize potential interferences between two systems. If successful, this proposal will lead to a truly simultaneous PET/MR hybrid system for whole body imaging. In addition to the benefits of PET/CT, the multiplicity of MR's anatomical information and PET's functional/molecular information will enable new paradigms for diseases diagnosis, prognosis and treatment in cancer screening/staging, cardiac imaging, therapy monitoring, and characterization of Alzheimer's disease. The proposed system will help physicians to detect diseases in the early stage with increase specificity and manage treatment plans more effectively. We believe that a simultaneous PET/MR system could ultimately make great impacts for advancing healthcare technology and improving quality of life in Canada. Economic benefits from commercialization and technology licensing through collaboration with industry partners are also expected.