Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of Toronto

$122,000.00

Development of advanced non-invasive dynamic photoacoustic and photothermal imaging technologies for biomedical and industrial diagnostics

EF 2024-25

Résumé
The proposed research projects constitute fundamental support of my ongoing research program at the Center for Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT) toward the development and targeted applications of new advanced photoacoustic (PA), photothermal (PT) and optoelectronic diffusion-wave (DW) imaging technologies pioneered in the CADIPT. In biomedical imaging the proposed research focuses on 3 PA and PT modalities: 1) Wavelength-Modulated Differential Photoacoustic Radar (WM-DPAR); 2) Wavelength-Modulated Differential Photothermal Radiometry (WM-DPTR); and 3) Enhanced Truncated-Correlation Photothermal Coherence Tomography (TC-PCT). The light-to-ultrasound (US) WM-DPAR and light-to-thermal-wave WM-DPTR and TC-PCT energy conversion nature and the very efficient signal baseline suppression of these modalities are very promising for diagnosis of diseases at very early stages and form the major criterion for designing the objectives of the proposed research. WM-DPAR features low-cost continuous wave (CW) laser-wavelength modulation, ~ 2-3 cm depth resolution, and can be integrated into commercial ultrasound imagers to add spectroscopic molecular contrast enhancement to the US image. WM-DPTR operates on laser induced blackbody emissions in the mid-infrared spectral range and features simpler instrumentation than PA, no coupling fluid and portability. TC-PCT is a high axial-resolution (25 um) PT 3D imaging method, also based on laser-induced mid-infrared photon emissions and ~4 mm depth resolution. Applications of the aforementioned modalities are proposed in three major areas: 1) Minimally- invasive clinically compatible WM-DPAR catheter development for early coronary artery disease (atherosclerosis) diagnosis; 2) A non-invasive WM-DPTR cannabis sensor for roadside monitoring of impaired driver tetrahydrocannabinol (THC; the psychoactive component of cannabis) interstitial fluid (strongly related to blood) concentration; and 3) Real-time noninvasive measurements of brown fat metabolism based on eTC-PCT imaging of hemoglobin time transients (gradients) in healthy and obese/diabetic mice, subjected to a high fat diet.. It is also proposed to develop Ultra-High Frequency Heterodyne Lock-In Carrierography (UHF-HeLIC) imaging as a unique non-contacting nondestructive optoelectronic DW inspection tool of entire surface areas of semiconductors, specifically rapid-growth clean energy ultrathin photovoltaic Si solar cell technologies. A unique feature of UHF-He LIC is that it can replace conventional localized electrical testing requiring finished electronic devices with all-optical noncontact measurements of e.g. current-voltage characteristics, allowing fast, wafer-level inspections at any and all device fabrication stages with no need for electrical leads. The imaging will identify and help minimize optoelectronic surface and bulk traps and assess the effectiveness of surface passivation and wet cleans in ultrathin PV devices.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RGPIN-2020-04595
Name nom
Mandelis, Andreas
Department département
Mechanical and Industrial Engineering - Mechanical and Industrial Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2020
Award amount
122000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Development of advanced non-invasive dynamic photoacoustic and photothermal imaging technologies for biomedical and industrial diagnostics
Keywords
biomedical imaging; wavelength-modulated photoacoustic radar; truncated-correlation photothermal coherence tomography; wavelength-modulated differential photothermal radiometry; endoscopic coronary artery imaging; cannabis biosensors; lock-in carrierography; photovoltaics - optoelectronic imaging; photoacoustics and thermophotonics; non-destructive imaging
Application summary
The proposed research projects constitute fundamental support of my ongoing research program at the Center for Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT) toward the development and targeted applications of new advanced photoacoustic (PA), photothermal (PT) and optoelectronic diffusion-wave (DW) imaging technologies pioneered in the CADIPT. In biomedical imaging the proposed research focuses on 3 PA and PT modalities: 1) Wavelength-Modulated Differential Photoacoustic Radar (WM-DPAR); 2) Wavelength-Modulated Differential Photothermal Radiometry (WM-DPTR); and 3) Enhanced Truncated-Correlation Photothermal Coherence Tomography (TC-PCT). The light-to-ultrasound (US) WM-DPAR and light-to-thermal-wave WM-DPTR and TC-PCT energy conversion nature and the very efficient signal baseline suppression of these modalities are very promising for diagnosis of diseases at very early stages and form the major criterion for designing the objectives of the proposed research. WM-DPAR features low-cost continuous wave (CW) laser-wavelength modulation, ~ 2-3 cm depth resolution, and can be integrated into commercial ultrasound imagers to add spectroscopic molecular contrast enhancement to the US image. WM-DPTR operates on laser induced blackbody emissions in the mid-infrared spectral range and features simpler instrumentation than PA, no coupling fluid and portability. TC-PCT is a high axial-resolution (25 um) PT 3D imaging method, also based on laser-induced mid-infrared photon emissions and ~4 mm depth resolution. Applications of the aforementioned modalities are proposed in three major areas: 1) Minimally- invasive clinically compatible WM-DPAR catheter development for early coronary artery disease (atherosclerosis) diagnosis; 2) A non-invasive WM-DPTR cannabis sensor for roadside monitoring of impaired driver tetrahydrocannabinol (THC; the psychoactive component of cannabis) interstitial fluid (strongly related to blood) concentration; and 3) Real-time noninvasive measurements of brown fat metabolism based on eTC-PCT imaging of hemoglobin time transients (gradients) in healthy and obese/diabetic mice, subjected to a high fat diet.. It is also proposed to develop Ultra-High Frequency Heterodyne Lock-In Carrierography (UHF-HeLIC) imaging as a unique non-contacting nondestructive optoelectronic DW inspection tool of entire surface areas of semiconductors, specifically rapid-growth clean energy ultrathin photovoltaic Si solar cell technologies. A unique feature of UHF-He LIC is that it can replace conventional localized electrical testing requiring finished electronic devices with all-optical noncontact measurements of e.g. current-voltage characteristics, allowing fast, wafer-level inspections at any and all device fabrication stages with no need for electrical leads. The imaging will identify and help minimize optoelectronic surface and bulk traps and assess the effectiveness of surface passivation and wet cleans in ultrathin PV devices.