Grant: Research Tools and Instruments

McMaster University

$150,000.00

Vector Network Analyzer for Medical Imaging Research

EF 2021-22

Résumé
Our research focuses on new medical diagnostic modalities using RF and microwave technologies. In support of this research, we request funding for a vector network analyzer (VNA) with a frequency range up to 40 GHz. It provides frequency-sweep measurements of the scattering parameters of high-frequency devices and circuits along with two additional functionalities: frequency-conversion measurements and time-domain measurements. The requested instrument will replace two VNAs that are now malfunctioning and obsolete. The problems with our old VNAs brought to a halt experimental work, which is critical to the progress of our trainees and the success of our research projects.    There are three research programs that depend critically on the requested instrument. First, we are in the advanced stages of developing a microwave-imaging prototype for breast-cancer screening. It will provide a much needed non-ionizing alternative to mammography with equivalent or better diagnostic accuracy, wider accessibility, reduced cost, increased check-up frequency, and improved patient safety. Its modules have been undergoing tests with breast-tissue phantoms in preparation for trials with patients but these tests are now on hold. This also includes the development of a new ultra-wideband (UWB) receiver chip, to be integrated within each antenna in the breast-imaging sensor array. The chip tape-out is expected in 2022 and its characterization will require frequency-conversion measurements with a VNA.    Second, we are working on novel coil designs for a 7T magnetic resonance imaging (MRI) scanner and in vivo nuclear magnetic resonance (NMR) spectroscopy. 7T MR spectroscopy will significantly enhance the diagnostic accuracy for brain and peripheral nerve tumors, epilepsy, multiple sclerosis and other neurodegenerative diseases. MRI coil testing requires measurements with a VNA for coil tuning and to validate the coil impedance match and coupling. We also pursue the biomedical applications of electron spin resonance (ESR) spectroscopy, which requires measurements at the X-band (10 GHz, 0.33 T) and the Q-band (35 GHz, 1.25 T).    Third, we work on new radiometers to overcome the current limitations of poor linearity and limited accuracy. Medical radiometers are attractive due to their passive nature - they do not irradiate the patient; they only sense the natural thermal radiation from the body. They are used to monitor the deep-body temperature during hyperthermia and thermal-ablation therapies. High-sensitivity radiometers are used in the emerging thermographic imaging of tissue for the detection of malignancies.    Experiment-based research is critical in achieving high-impact innovation through the projects described above. It is needed not only for the development of hardware with new functionalities but also to support the development of new methods for image reconstruction and processing, anomaly detection, and automated diagnostics exploiting machine learning.
Programme
Research Tools and Instruments
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RTI-2022-00407
Name nom
Nikolova, Natalia
Department département
Electrical and Computer Engineering
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2021
Competition year année de concours
2022
Award amount
150000
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1610
Committee name en
Electrical and Computer Engineering (RTI)
Committee name fr
Génie électrique et infomatique (OIR)
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2518
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Instrumentation and measurements
Research subject fr
Instrumentation et mesures
Installment
inst:1
Partie
1
Nb partie
1
Application title
Vector Network Analyzer for Medical Imaging Research
Keyword
NSERC
Application summary
Our research focuses on new medical diagnostic modalities using RF and microwave technologies. In support of this research, we request funding for a vector network analyzer (VNA) with a frequency range up to 40 GHz. It provides frequency-sweep measurements of the scattering parameters of high-frequency devices and circuits along with two additional functionalities: frequency-conversion measurements and time-domain measurements. The requested instrument will replace two VNAs that are now malfunctioning and obsolete. The problems with our old VNAs brought to a halt experimental work, which is critical to the progress of our trainees and the success of our research projects.    There are three research programs that depend critically on the requested instrument. First, we are in the advanced stages of developing a microwave-imaging prototype for breast-cancer screening. It will provide a much needed non-ionizing alternative to mammography with equivalent or better diagnostic accuracy, wider accessibility, reduced cost, increased check-up frequency, and improved patient safety. Its modules have been undergoing tests with breast-tissue phantoms in preparation for trials with patients but these tests are now on hold. This also includes the development of a new ultra-wideband (UWB) receiver chip, to be integrated within each antenna in the breast-imaging sensor array. The chip tape-out is expected in 2022 and its characterization will require frequency-conversion measurements with a VNA.    Second, we are working on novel coil designs for a 7T magnetic resonance imaging (MRI) scanner and in vivo nuclear magnetic resonance (NMR) spectroscopy. 7T MR spectroscopy will significantly enhance the diagnostic accuracy for brain and peripheral nerve tumors, epilepsy, multiple sclerosis and other neurodegenerative diseases. MRI coil testing requires measurements with a VNA for coil tuning and to validate the coil impedance match and coupling. We also pursue the biomedical applications of electron spin resonance (ESR) spectroscopy, which requires measurements at the X-band (10 GHz, 0.33 T) and the Q-band (35 GHz, 1.25 T).    Third, we work on new radiometers to overcome the current limitations of poor linearity and limited accuracy. Medical radiometers are attractive due to their passive nature - they do not irradiate the patient; they only sense the natural thermal radiation from the body. They are used to monitor the deep-body temperature during hyperthermia and thermal-ablation therapies. High-sensitivity radiometers are used in the emerging thermographic imaging of tissue for the detection of malignancies.    Experiment-based research is critical in achieving high-impact innovation through the projects described above. It is needed not only for the development of hardware with new functionalities but also to support the development of new methods for image reconstruction and processing, anomaly detection, and automated diagnostics exploiting machine learning.