Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Collaborative Research and Development Grants

University of Saskatchewan

$60,000.00

Doped n-type a-Se alloys for use in x-ray image detectors: preparation, thermal and electrical properties

EF 2012-13

Résumé
The proposed NSERC-CRD grant is in collaboration with the Analogic Canada (Anrad) Corporation in Montreal, and has the overall goal of synthesizing and characterizing stabilized n-type a-Se alloys in which the stabilization is achieved by increasing the As content from 2% to 10%A. The n-type a-Se is used in one of the key-layers in the a-Se x-ray image detector next to the positively biased metal electrode to reduce the dark current. However, the doping of a-Se with n-type dopants tends to crystallize the structure over time, and it is more difficult to fabricate than the i-layer. The goal of this CRD is to synthesize a range of Se(1-x)As(x) alloys with As content varied from 0.3 to 10%, and the alloys doped with various IA and IIA elements, and characterize their structural, thermal and electrical properties. The CRD project involves the following research: (a) synthesis of the base Se(1-x)As(x) alloys; (b) n-type doping of these Se(1-x)Se(x) alloys; (c) structural and thermal characterization of the new n-type alloys through differential scanning calorimetry (DSC) and temperature-modulated DSC to obtain the glass transition, crystallization and melting temperature, the heat capacity, relaxation and crystallization enthalpies, crystallization kinetics; (d) electrical properties through charge transport measurements (such as transient photoconductivity type time-of-flight measurements), dark current measurements, and excess noise experiments. The experimental work will be supplemented by the formulation of new useful models for the dark current so that it can be predicted as a function of time and applied field from the intrinsic material properties for x-ray detectors that will have the new n-type a-Se layer. The proposed CRD grant builds on the expertise gained in the previous CRD and therefore starts from an already established know-how and builds on strength. The results are expected to lead to enhancements in detector performance in terms of having the n-layer in the detector thinner and higher production yield. The research directly impacts a-Se x-ray detectors currently used in mammography; and also therefore impacts the healthcare of women (breast cancer screening).
Programme
Collaborative Research and Development Grants
Emplacement
Saskatchewan, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
434690-2012
Name nom
Kasap, Safa
Department département
Electrical & Computer Engineering
Organization id
16
Institution établissement
University of Saskatchewan
Province en
Saskatchewan
Province fr
Saskatchewan
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
60000
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2515
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electronic materials and components
Research subject fr
Matériels et composants électroniques
Partie
1
Nb partie
3
Application title
Doped n-type a-Se alloys for use in x-ray image detectors: preparation, thermal and electrical properties
Keyword
NSERC
Application summary
The proposed NSERC-CRD grant is in collaboration with the Analogic Canada (Anrad) Corporation in Montreal, and has the overall goal of synthesizing and characterizing stabilized n-type a-Se alloys in which the stabilization is achieved by increasing the As content from 2% to 10%A. The n-type a-Se is used in one of the key-layers in the a-Se x-ray image detector next to the positively biased metal electrode to reduce the dark current. However, the doping of a-Se with n-type dopants tends to crystallize the structure over time, and it is more difficult to fabricate than the i-layer. The goal of this CRD is to synthesize a range of Se(1-x)As(x) alloys with As content varied from 0.3 to 10%, and the alloys doped with various IA and IIA elements, and characterize their structural, thermal and electrical properties. The CRD project involves the following research: (a) synthesis of the base Se(1-x)As(x) alloys; (b) n-type doping of these Se(1-x)Se(x) alloys; (c) structural and thermal characterization of the new n-type alloys through differential scanning calorimetry (DSC) and temperature-modulated DSC to obtain the glass transition, crystallization and melting temperature, the heat capacity, relaxation and crystallization enthalpies, crystallization kinetics; (d) electrical properties through charge transport measurements (such as transient photoconductivity type time-of-flight measurements), dark current measurements, and excess noise experiments. The experimental work will be supplemented by the formulation of new useful models for the dark current so that it can be predicted as a function of time and applied field from the intrinsic material properties for x-ray detectors that will have the new n-type a-Se layer. The proposed CRD grant builds on the expertise gained in the previous CRD and therefore starts from an already established know-how and builds on strength. The results are expected to lead to enhancements in detector performance in terms of having the n-layer in the detector thinner and higher production yield. The research directly impacts a-Se x-ray detectors currently used in mammography; and also therefore impacts the healthcare of women (breast cancer screening).