Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

McMaster University

$22,000.00

""Seismic Protection Technologies to Improve the Performance of Nonstructural Components, Equipment and Contents""

EF 2016-17

Résumé
The value of nonstructural components, equipment and contents (NCEC) in a typical commercial building dwarfs the cost of the structure itself. Consequently, a very significant portion of the total potential losses in the event of an earthquake is due to NCEC damage. While satisfying structural performance criteria in a seismic event is imperative to prevent casualties, it is by itself of lesser importance if NCEC performance criteria are not met. Failure to satisfy such criteria can result in possible interrupted operation and costly repairs. Seismic protection technologies, such as seismic isolation and energy dissipation devices, follow an approach to earthquake resistant design that is based on reducing the seismic demand on a structure rather than increasing the seismic capacity of the structure. While it is expected that such technologies will reduce the seismic demand on NCEC, thus improving their performance, the structural engineering community currently does not integrate NCEC in the analysis and performance assessment process. However, as emphasis on performance-based design increases, the new generation of building codes will be shifting away from prescriptive provisions and moving towards performance-based approaches, focusing on system-level performance. This creates an urgent need to generate the necessary knowledge to improve our understanding of the seismic performance of NCEC; and to examine how earthquake protection technologies can be incorporated in the design of buildings to improve the performance of the integral structural-nonstructural system, which includes NCEC. The integration of NCEC performance into the system-level performance assessment will significantly impact the way buildings that feature earthquake protection technologies are designed. The findings of the research program will contribute to seismic isolation provisions in future versions of the NBCC and in the development of the next CSA S832 ""Risk Reduction of Operational and Functional Components (OFCs) of Buildings"" standard.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
418616-2012
Name nom
Konstantinidis, Dimitrios
Department département
Civil Engineering
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2012
Award amount
22000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1509
Committee name en
Civil, Industrial and Systems Engineering
Committee name fr
Génie civil, industriel et des systèmes
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1107
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Earthquake engineering
Research subject fr
Génie parasismique
Partie
5
Nb partie
6
Application title
""Seismic Protection Technologies to Improve the Performance of Nonstructural Components, Equipment and Contents""
Keyword
NSERC
Application summary
The value of nonstructural components, equipment and contents (NCEC) in a typical commercial building dwarfs the cost of the structure itself. Consequently, a very significant portion of the total potential losses in the event of an earthquake is due to NCEC damage. While satisfying structural performance criteria in a seismic event is imperative to prevent casualties, it is by itself of lesser importance if NCEC performance criteria are not met. Failure to satisfy such criteria can result in possible interrupted operation and costly repairs. Seismic protection technologies, such as seismic isolation and energy dissipation devices, follow an approach to earthquake resistant design that is based on reducing the seismic demand on a structure rather than increasing the seismic capacity of the structure. While it is expected that such technologies will reduce the seismic demand on NCEC, thus improving their performance, the structural engineering community currently does not integrate NCEC in the analysis and performance assessment process. However, as emphasis on performance-based design increases, the new generation of building codes will be shifting away from prescriptive provisions and moving towards performance-based approaches, focusing on system-level performance. This creates an urgent need to generate the necessary knowledge to improve our understanding of the seismic performance of NCEC; and to examine how earthquake protection technologies can be incorporated in the design of buildings to improve the performance of the integral structural-nonstructural system, which includes NCEC. The integration of NCEC performance into the system-level performance assessment will significantly impact the way buildings that feature earthquake protection technologies are designed. The findings of the research program will contribute to seismic isolation provisions in future versions of the NBCC and in the development of the next CSA S832 ""Risk Reduction of Operational and Functional Components (OFCs) of Buildings"" standard.