Grant: Discovery Grants Program - Individual
Concordia University
$25,000.00
Photoconductors for radiation imaging detectors: materials issues and device designs
EF 2016-17
Résumé
There is a huge demand for lowering irradiation dose in various medical radiation imaging modalities especially in general X-ray radiography and real-time radiation imaging. After last two decades of extensive research, amorphous selenium (a-Se) based direct conversion flat-panel digital X-ray detector (the incident X-rays directly generate charge carriers in the photoconductor layer) is recently commercialized for digital mammography. The a-Se detector is not perfect and the main drawback of the conventional a-Se detector under normal operation is its low sensitivity compared to other potential photoconductors such as polycrystalline lead oxide or mercuric iodide. Low sensitivity gives low signal to noise ratio in low-dose imaging and thus severely affects the diagnostic features of the image. Very low-dose medical X-ray imaging could be achieved by; (1) utilizing avalanche multiplication process at a very high electric field in a-Se layer for higher charge signal, and/or (2) replacing a-Se by other potential photoconductors that can provide higher collected charge. Low-cost X-ray imaging can be obtained by utilizing organic photoconductors in X-ray detectors. The research on avalanche a-Se solid state imaging detector is in a very premature level; it needs extensive research works to clearly understand the fundamental underlying physics of carrier generation, multiplication, and transport mechanisms, and to optimize the detector design by examining imaging performances.
The PI's research program will endeavor to develop low-dose and/or low-cost medical X-ray/optical imaging detectors by extensively investigating charge carrier generation, transport, multiplication, and noise creation mechanisms in photoconductors, developing mathematical models for analyzing imaging detector performances such as dark current, sensitivity, DQE (detective quantum efficiency), and MTF (modulation transfer function) as a function of field, temperature, detector structure, X-ray induced effects, excess noise, and hence optimizing the detector designs.
The proposed work is vital to understand the fundamental physics of X-ray/optical detector operations and photoconductor properties, and to identify the important factors that limit the detector performances, which can ultimately lead to finding the efficient materials and designs for low-cost and efficient radiation imaging detectors for various digital medical imaging applications. This research will advance scientific knowledge in high field transport mechanisms in amorphous and polycrystalline photoconductors. The mathematical models can be used as design tools by researchers in academia and industries. The proposed work has excellent scope for original and fundamental research for graduate students, which will advance fundamental scientific knowledge and transfer it to the next generation. This research will be beneficial to Canada's R&D efforts in medical digital imaging, and the digital radiation image detector community (e.g., Analogic and Hologic).
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RGPIN-2014-06103
Name nom
Kabir, MZahangir
Department département
Electrical and Computer Engineering
Organization id
70
Institution établissement
Concordia University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2014
Award amount
25000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2515
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electronic materials and components
Research subject fr
Matériels et composants électroniques
Partie
3
Nb partie
5
Application title
Photoconductors for radiation imaging detectors: materials issues and device designs
Keyword
NSERC
Application summary
There is a huge demand for lowering irradiation dose in various medical radiation imaging modalities especially in general X-ray radiography and real-time radiation imaging. After last two decades of extensive research, amorphous selenium (a-Se) based direct conversion flat-panel digital X-ray detector (the incident X-rays directly generate charge carriers in the photoconductor layer) is recently commercialized for digital mammography. The a-Se detector is not perfect and the main drawback of the conventional a-Se detector under normal operation is its low sensitivity compared to other potential photoconductors such as polycrystalline lead oxide or mercuric iodide. Low sensitivity gives low signal to noise ratio in low-dose imaging and thus severely affects the diagnostic features of the image. Very low-dose medical X-ray imaging could be achieved by; (1) utilizing avalanche multiplication process at a very high electric field in a-Se layer for higher charge signal, and/or (2) replacing a-Se by other potential photoconductors that can provide higher collected charge. Low-cost X-ray imaging can be obtained by utilizing organic photoconductors in X-ray detectors. The research on avalanche a-Se solid state imaging detector is in a very premature level; it needs extensive research works to clearly understand the fundamental underlying physics of carrier generation, multiplication, and transport mechanisms, and to optimize the detector design by examining imaging performances.
The PI's research program will endeavor to develop low-dose and/or low-cost medical X-ray/optical imaging detectors by extensively investigating charge carrier generation, transport, multiplication, and noise creation mechanisms in photoconductors, developing mathematical models for analyzing imaging detector performances such as dark current, sensitivity, DQE (detective quantum efficiency), and MTF (modulation transfer function) as a function of field, temperature, detector structure, X-ray induced effects, excess noise, and hence optimizing the detector designs.
The proposed work is vital to understand the fundamental physics of X-ray/optical detector operations and photoconductor properties, and to identify the important factors that limit the detector performances, which can ultimately lead to finding the efficient materials and designs for low-cost and efficient radiation imaging detectors for various digital medical imaging applications. This research will advance scientific knowledge in high field transport mechanisms in amorphous and polycrystalline photoconductors. The mathematical models can be used as design tools by researchers in academia and industries. The proposed work has excellent scope for original and fundamental research for graduate students, which will advance fundamental scientific knowledge and transfer it to the next generation. This research will be beneficial to Canada's R&D efforts in medical digital imaging, and the digital radiation image detector community (e.g., Analogic and Hologic).