Grant: Engage Grants Program
École Polytechnique de Montréal
$25,000.00
Influence of the operating frequency and amplitude in an acoustic airway clearance device
EF 2017-18
Résumé
The company Dymedso (Boisbriand, QC) manufactures The Frequencer(TM), a digitally controlled acousticairway clearance device that promotes bronchial drainage by inducing vibrations in the chest wall of a patient.The Frequencer(TM) is recommended for patients affected by defective mucociliary clearance including cysticfibrosis (CF), chronic bronchitis, thoracic wall defects among other pathologies. With an operating frequencyof 20 to 65 Hz, The Frequencer(TM) provides a gentler therapy than the traditional ""clapping"" method orpostural drainage. Dymedso is looking to give an answer to its customers who claim a better mucous fluidity atfrequencies of 37 to 42 Hz. The lack of mucous fluidity in patients with CF is ascribable to its dehydration as aconsequence of insufficient excretion of NaCl to the airways, leading to the increase of secretion viscosity. Inthe project proposed we will realize a series of tests to elucidate possible mechanisms underlying the transportof water and salt (NaCl) in mucin solutions at different operating frequencies and powers of TheFrequencer(TM). The objective will be achieved applying the head of The Frequencer(TM) to the top of aad-hoc reactor containing biphasic mixtures of water and mucin solutions with salt. Besides water and saltconcentration in the artificial mucous after exposure to different operating frequencies and powers of theFrequencer(TM), we will quantify changes in mucous rheological behavior and develop a numerical model forwater and salt mass transfer through the mucin solutions.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
509484-2017
Name nom
Boffito, DariaCamilla
Department département
Génie chimique
Organization id
64
Institution établissement
École Polytechnique de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1805
Research subject group en
Chemical engineering
Research subject group fr
Génie chimique
Research subject en
Transport processes
Research subject fr
Procédés de transfert
Partie
1
Nb partie
1
Application title
Influence of the operating frequency and amplitude in an acoustic airway clearance device
Keyword
NSERC
Application summary
The company Dymedso (Boisbriand, QC) manufactures The Frequencer(TM), a digitally controlled acousticairway clearance device that promotes bronchial drainage by inducing vibrations in the chest wall of a patient.The Frequencer(TM) is recommended for patients affected by defective mucociliary clearance including cysticfibrosis (CF), chronic bronchitis, thoracic wall defects among other pathologies. With an operating frequencyof 20 to 65 Hz, The Frequencer(TM) provides a gentler therapy than the traditional ""clapping"" method orpostural drainage. Dymedso is looking to give an answer to its customers who claim a better mucous fluidity atfrequencies of 37 to 42 Hz. The lack of mucous fluidity in patients with CF is ascribable to its dehydration as aconsequence of insufficient excretion of NaCl to the airways, leading to the increase of secretion viscosity. Inthe project proposed we will realize a series of tests to elucidate possible mechanisms underlying the transportof water and salt (NaCl) in mucin solutions at different operating frequencies and powers of TheFrequencer(TM). The objective will be achieved applying the head of The Frequencer(TM) to the top of aad-hoc reactor containing biphasic mixtures of water and mucin solutions with salt. Besides water and saltconcentration in the artificial mucous after exposure to different operating frequencies and powers of theFrequencer(TM), we will quantify changes in mucous rheological behavior and develop a numerical model forwater and salt mass transfer through the mucin solutions.