Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Applied Research and Development Grants - Level 1

Red River College of Applied Arts, Science and Technology

$25,000.00

Improving water-based graphite colloidal system for a pressure-sensing fabric application

EF 2019-20

Résumé
Vista medical has been producing pressure-sensing fabric for use in medical devices and consumer products since 1992. The technology consists of a conductive fabric substrate to which a carbon colloidal system is applied. The coated fabric is then dried and further processed. The finished product is a fabric system that can convert pressure applied to it to an electrical signal, which upon processing can provide a pressure map. Vista Medical product is used in medical devices and consumer products.Currently, Vista Medical purchases both components needed to manufacture their product, namely the conductive fabric and the graphite colloid, from external sources. The manufacturing process at Vista Medical consists of applying the graphite colloid to the fabric, drying the coated fabric and converting it to the finished product as per customer specifications. Quality control for the product consists of verification of pressure readings and other fit-for-use tests.As evident from the above, the performance of Vista Medical products depends on the quality and consistency of the components purchased. For sometimes, it has been noticed that inconsistencies in characteristics of the purchased graphite colloid adversely affect the quality of the finished product. Test results and specifications in the Certificate of Analysis provided by the supplier of the colloidal graphite are also too broad to ensure product quality. This has resulted into loss of productivity and potential product quality issues. In order to overcome this challenge, Vista Medical has been looking into in-house manufacturing of the graphite colloid.
Programme
Applied Research and Development Grants - Level 1
Emplacement
Manitoba, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
543229-2019
Name nom
DelosReyes, JoseRizalino
Department département
Head Office
Organization id
22155
Institution établissement
Red River College of Applied Arts, Science and Technology
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2019
Award amount
25000
Program id
CARD1
Program name en
Applied Research and Development Grants - Level 1
Program name fr
Subventions de recherche et développement appliquée - niveau 1
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
1561
Committee name en
Applied Research and Development Grants
Committee name fr
Subventions de recherche et développement appliquée
Area of application code
508
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Polymers, rubber and plastics
Area of application fr
Polymères, caoutchouc et plastiques
Research subject code
3606
Research subject group en
Inorganic chemistry
Research subject group fr
Chimie inorganique
Research subject en
Kinetics and mechanisms of reactions
Research subject fr
Cinétique et mécanismes des réactions
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
Improving water-based graphite colloidal system for a pressure-sensing fabric application
Keyword
NSERC
Application summary
Vista medical has been producing pressure-sensing fabric for use in medical devices and consumer products since 1992. The technology consists of a conductive fabric substrate to which a carbon colloidal system is applied. The coated fabric is then dried and further processed. The finished product is a fabric system that can convert pressure applied to it to an electrical signal, which upon processing can provide a pressure map. Vista Medical product is used in medical devices and consumer products.Currently, Vista Medical purchases both components needed to manufacture their product, namely the conductive fabric and the graphite colloid, from external sources. The manufacturing process at Vista Medical consists of applying the graphite colloid to the fabric, drying the coated fabric and converting it to the finished product as per customer specifications. Quality control for the product consists of verification of pressure readings and other fit-for-use tests.As evident from the above, the performance of Vista Medical products depends on the quality and consistency of the components purchased. For sometimes, it has been noticed that inconsistencies in characteristics of the purchased graphite colloid adversely affect the quality of the finished product. Test results and specifications in the Certificate of Analysis provided by the supplier of the colloidal graphite are also too broad to ensure product quality. This has resulted into loss of productivity and potential product quality issues. In order to overcome this challenge, Vista Medical has been looking into in-house manufacturing of the graphite colloid.