Grant: Engage Grants Program
University of British Columbia
$24,250.00
A study on feasibility of VOC sensor integration
EF 2015-16
Résumé
Island Clean Air Inc. (ICA) is a Vancouver-based company that designs, manufactures, and markets a wide
range of air filtration units for different industries, such as automobile paint shop, print and graphics, etc. These
systems are fitted with three stage filters that are capable of removing particulate matter (PM) as well as
volatile organic compounds (VOCs) from the air. They are user friendly and operated at a user-defined air flow
rate, and the only cost involved is operational (electric energy) and maintenance (filter replacement). According
to the ICA technical team, the filters have to be replaced every 6 months when operating under average
conditions such as in a workshop, or every 2-3 months for extremely polluted air. These systems use an
integrated flow meter to detect when a significant amount of PM has accumulated on the filters. At that point,
an indicator lights up that recommends the user to change the air filter. However, there is currently no sensor
on these units that provides information on the air quality in real time for the user to observe the efficiency of
the filtration system increasing the air quality over time. Such a feature could also have the user turn off the
filtration system when the air is sufficiently clean in order to reduce the operational and maintenance cost, and
improve efficiency and life time of the filters.
Ideally, one would integrate a VOC sensing system with a filtration unit to provide immediate feedback to the
user on real-time air quality. Using two such sensors, one upstream and one downstream from the filter would
allow measuring whether the filter is saturated with VOCs, which could occur before accumulation of a
significant amount of PM
The integration of VOCs sensor to ICA's air filtration systems will give the company a significant competitive
advantage over their competitors. ICA would then be the only company that can provide a real-time assessment
of air cleanliness as well as their filtration efficiency, as well as a way to turn down the system in order to save
energy.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
478780-2015
Name nom
Walus, Konrad
Department département
Electrical and Computer Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
24250
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
401
Area of application group en
Environment
Area of application group fr
Environnement
Area of application en
Climate and atmosphere
Area of application fr
Climat et atmosphère
Research subject code
2506
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electron devices
Research subject fr
Dispositifs électroniques
Partie
1
Nb partie
1
Application title
A study on feasibility of VOC sensor integration
Keyword
NSERC
Application summary
Island Clean Air Inc. (ICA) is a Vancouver-based company that designs, manufactures, and markets a wide
range of air filtration units for different industries, such as automobile paint shop, print and graphics, etc. These
systems are fitted with three stage filters that are capable of removing particulate matter (PM) as well as
volatile organic compounds (VOCs) from the air. They are user friendly and operated at a user-defined air flow
rate, and the only cost involved is operational (electric energy) and maintenance (filter replacement). According
to the ICA technical team, the filters have to be replaced every 6 months when operating under average
conditions such as in a workshop, or every 2-3 months for extremely polluted air. These systems use an
integrated flow meter to detect when a significant amount of PM has accumulated on the filters. At that point,
an indicator lights up that recommends the user to change the air filter. However, there is currently no sensor
on these units that provides information on the air quality in real time for the user to observe the efficiency of
the filtration system increasing the air quality over time. Such a feature could also have the user turn off the
filtration system when the air is sufficiently clean in order to reduce the operational and maintenance cost, and
improve efficiency and life time of the filters.
Ideally, one would integrate a VOC sensing system with a filtration unit to provide immediate feedback to the
user on real-time air quality. Using two such sensors, one upstream and one downstream from the filter would
allow measuring whether the filter is saturated with VOCs, which could occur before accumulation of a
significant amount of PM
The integration of VOCs sensor to ICA's air filtration systems will give the company a significant competitive
advantage over their competitors. ICA would then be the only company that can provide a real-time assessment
of air cleanliness as well as their filtration efficiency, as well as a way to turn down the system in order to save
energy.