Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

University of British Columbia

$25,000.00

Lateral capacity of protected and unprotected steel columns under fire hazards

EF 2011-12

Résumé
Steel structures are commonly used for residential, commercial and industrial buildings in North America for its faster construction and availability of the material. Reported literature suggests that steel columns are extremely vulnerable when exposed to fire condition, since their strength and capacity decrease substantially at high temperature. Besides, in an uncontrolled fire event, the structure may experience significant lateral deformation. However, there is no strict guideline about the lateral resistances of steel columns under fire. Therefore, the proposed research aims at investigating the performance of steel columns presented in CISC (Canadian Institute of Steel Construction) under lateral load and elevated temperature due to fire exposure. Different steel sections of various heights will be chosen for columns based on existing Canadian practices in the steel construction industry. Various fire retardant coatings like fire brick, vermiculite board, gypsum board, fire-retardant spray and heavy clay brick that are used for steel columns to slow down the heat transfer from fire to steel components will be considered in this study. This research will develop tools and guidelines for practitioners that will assist them in predicting the lateral load resistance of unprotected and protected steel columns of various sections and heights during a fire event. The lateral load-deflection, moment-rotation, lateral load capacity, moment capacity, stiffness and ductility will be studied under fire exposure. This study will also provide some cost-effective solutions (optimum thickness) to fire protection of columns from various alternatives. The results of different temperatures and fire exposure time will be presented in useful graphical formats where the lateral capacity of various steel column sections of different heights can be readily known at different fire exposure times, and structural engineers and practitioners can apply this knowledge readily in their design. Thus, the significance of this research is paramount as it directly contributes to the fire safety and security to Canadian building infrastructure.
Programme
Engage Grants Program
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
413131-2011
Name nom
Alam, Shahria
Department département
Okanagan - Engineering, School of
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2011
Award amount
25000
Program id
EGP
Program nane en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1102
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Steel structures
Research subject fr
Structures en acier
Partie
1
Nb partie
1
Application title
Lateral capacity of protected and unprotected steel columns under fire hazards
Keyword
NSERC
Application summary
Steel structures are commonly used for residential, commercial and industrial buildings in North America for its faster construction and availability of the material. Reported literature suggests that steel columns are extremely vulnerable when exposed to fire condition, since their strength and capacity decrease substantially at high temperature. Besides, in an uncontrolled fire event, the structure may experience significant lateral deformation. However, there is no strict guideline about the lateral resistances of steel columns under fire. Therefore, the proposed research aims at investigating the performance of steel columns presented in CISC (Canadian Institute of Steel Construction) under lateral load and elevated temperature due to fire exposure. Different steel sections of various heights will be chosen for columns based on existing Canadian practices in the steel construction industry. Various fire retardant coatings like fire brick, vermiculite board, gypsum board, fire-retardant spray and heavy clay brick that are used for steel columns to slow down the heat transfer from fire to steel components will be considered in this study. This research will develop tools and guidelines for practitioners that will assist them in predicting the lateral load resistance of unprotected and protected steel columns of various sections and heights during a fire event. The lateral load-deflection, moment-rotation, lateral load capacity, moment capacity, stiffness and ductility will be studied under fire exposure. This study will also provide some cost-effective solutions (optimum thickness) to fire protection of columns from various alternatives. The results of different temperatures and fire exposure time will be presented in useful graphical formats where the lateral capacity of various steel column sections of different heights can be readily known at different fire exposure times, and structural engineers and practitioners can apply this knowledge readily in their design. Thus, the significance of this research is paramount as it directly contributes to the fire safety and security to Canadian building infrastructure.