GFRP Shear Studs for GFRP-RC Flat Slab-Column Connections

EF 2015-16

Résumé
Pultrall is a leading Canadian manufacturer of composite materials for various applications including products related to transportation, medical, military and construction industry. One of these applications is the development of non-corrodible, fibre-reinforced polymer (FRP) reinforcing bars for concrete structures using the pultrusion process. These bars have proven to be an excellent alternative for steel reinforcement provided that steel corrosion is the main cause of deterioration of reinforced concrete (RC) structures especially those in harsh environments such as bridges and parking structures. A large number of parking structures in North America are constructed using flat plate structures in which flat slabs are directly supported on columns. In these structures, the transverse punching shear at the two-way slab-column connections usually governs the design. Besides, punching shear failure is usually brittle, sudden and catastrophic in nature and, therefore, it should be certainly avoided. Providing well-anchored transverse (shear) reinforcement results in significantly thinner slabs (much less cost) with significant deformation (ample warning) before failure. Pultrall is in the process of developing a new product, GFRP studs, to reinforce such connections in shear. The main issue is the small slab thickness (200-300 mm) in which the development of adequate bond or anchorage is a challenge. A short length (150-250 mm), double-headed GFRP bars are proposed to be used as shear studs. The current production method for headed bars requires a length of at least 60-70 mm per head for size 13 (12.7-mm diameter) bars; larger size bars require longer heads. To develop such a new product (bar diameter, corresponding head size and usable strain), it requires full-scale testing of RC slab-column connections using different GFRP shear stud patterns (size, extend and arrangement) in the vicinity of the column.
Programme
Engage Grants Program
Emplacement
Manitoba, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
485361-2015
Name nom
El-Salakawy, Ehab
Department département
Civil Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
1
Nb partie
1
Application title
GFRP Shear Studs for GFRP-RC Flat Slab-Column Connections
Keyword
NSERC
Application summary
Pultrall is a leading Canadian manufacturer of composite materials for various applications including products related to transportation, medical, military and construction industry. One of these applications is the development of non-corrodible, fibre-reinforced polymer (FRP) reinforcing bars for concrete structures using the pultrusion process. These bars have proven to be an excellent alternative for steel reinforcement provided that steel corrosion is the main cause of deterioration of reinforced concrete (RC) structures especially those in harsh environments such as bridges and parking structures. A large number of parking structures in North America are constructed using flat plate structures in which flat slabs are directly supported on columns. In these structures, the transverse punching shear at the two-way slab-column connections usually governs the design. Besides, punching shear failure is usually brittle, sudden and catastrophic in nature and, therefore, it should be certainly avoided. Providing well-anchored transverse (shear) reinforcement results in significantly thinner slabs (much less cost) with significant deformation (ample warning) before failure. Pultrall is in the process of developing a new product, GFRP studs, to reinforce such connections in shear. The main issue is the small slab thickness (200-300 mm) in which the development of adequate bond or anchorage is a challenge. A short length (150-250 mm), double-headed GFRP bars are proposed to be used as shear studs. The current production method for headed bars requires a length of at least 60-70 mm per head for size 13 (12.7-mm diameter) bars; larger size bars require longer heads. To develop such a new product (bar diameter, corresponding head size and usable strain), it requires full-scale testing of RC slab-column connections using different GFRP shear stud patterns (size, extend and arrangement) in the vicinity of the column.