Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Collaborative Research and Development Grants

McGill University

$46,500.00

Improved design and safety of shear plate and slotted tube connections

EF 2012-13

Résumé
The proposed research project is directed towards improving the current design and detailing provisions in Canada for structural steel connections. ADF Group Inc., representing steel fabricators in this country, and their engineers (DPHV) have expressed concern with respect to the existing design procedures and potential performance of shear tab beam connections. Similarly, a more cost effective and ductile configuration, as well as corresponding design approach, is sought for slotted HSS brace connections. Shear tabs are commonly used throughout Canada to connect structural steel beams to column or girder members. The current design procedure recommended by the Canadian Institute of Steel Construction (CISC, 2006) is limited to relatively small configurations with a single row of bolts. The design procedure does not address the use of multiple rows of bolts, heavily loaded connections, extended shear plate connections, combined axial and shear forces in the connection, nor the typical weld retrofit measures taken when bolt holes do not align. Slotted HSS brace connections are prone to fracture under the repeated inelastic cyclic deformations associated with seismic loading. At present, in order to account for this failure mode fabricators must reinforce these connections, which adds significant cost. A revised connection is needed that provides for enhanced inelastic performance without reinforcement. The overall objective of this proposed research project is to develop improved design and detailing guidelines for shear tabs and slotted HSS connections. This will be achieved through the completion of an extensive program of tests, finite element analyses and design evaluation. With this information the steel industry in general, fabricators and engineers such as DPHV will be able to more accurately and cost effectively design and construct shear tab and slotted HSS connections. This will place ADF and the steel industry in an advantageous position compared with competing structural materials. Ultimately, the improved design procedures and level of performance of these connections will be of benefit with respect to the safety of building occupants and owners.
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
380561-2008
Name nom
Rogers, Colin
Department département
Civil Engineering and Applied Mechanics
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2008
Award amount
46500
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1102
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Steel structures
Research subject fr
Structures en acier
Partie
4
Nb partie
4
Application title
Improved design and safety of shear plate and slotted tube connections
Keyword
NSERC
Application summary
The proposed research project is directed towards improving the current design and detailing provisions in Canada for structural steel connections. ADF Group Inc., representing steel fabricators in this country, and their engineers (DPHV) have expressed concern with respect to the existing design procedures and potential performance of shear tab beam connections. Similarly, a more cost effective and ductile configuration, as well as corresponding design approach, is sought for slotted HSS brace connections. Shear tabs are commonly used throughout Canada to connect structural steel beams to column or girder members. The current design procedure recommended by the Canadian Institute of Steel Construction (CISC, 2006) is limited to relatively small configurations with a single row of bolts. The design procedure does not address the use of multiple rows of bolts, heavily loaded connections, extended shear plate connections, combined axial and shear forces in the connection, nor the typical weld retrofit measures taken when bolt holes do not align. Slotted HSS brace connections are prone to fracture under the repeated inelastic cyclic deformations associated with seismic loading. At present, in order to account for this failure mode fabricators must reinforce these connections, which adds significant cost. A revised connection is needed that provides for enhanced inelastic performance without reinforcement. The overall objective of this proposed research project is to develop improved design and detailing guidelines for shear tabs and slotted HSS connections. This will be achieved through the completion of an extensive program of tests, finite element analyses and design evaluation. With this information the steel industry in general, fabricators and engineers such as DPHV will be able to more accurately and cost effectively design and construct shear tab and slotted HSS connections. This will place ADF and the steel industry in an advantageous position compared with competing structural materials. Ultimately, the improved design procedures and level of performance of these connections will be of benefit with respect to the safety of building occupants and owners.