Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

York University

$25,000.00

A label-free thermoelectric reader for quantitative interpretation of results from single- and multi-test lateral flow assay devices

EF 2014-15

Résumé
The research and development that will be carried out in this project is to resolve an important problem withautomated, quantitative and label-free interpretation of results from Lateral Flow Assay (LFA) devices such asthe home-used pregnancy test strips. LFA devices have gained great popularity for their effective applications inmedical diagnosis, food and beverage manufacturing and water monitoring to name a few. These devices areused to detect the presence of specific analytes such as hormones, toxic chemicals or pathogenicmicroorganisms in many different fluidic specimens. Their working principle is very simple, target analytes getattached to colored nanoparticles via specific capturing reagents coated on the nanoparticles, and thenanoparticles become immobilized along detection line bands on the device as the specimen flows through it.Continuous accumulation of analyte-nanoparticle complexes along the line bands leads to the generation ofvisible lines and qualitative interpretation of results (i.e. yes or no). But, visual interpretation is inaccurate,subjective and most importantly non-quantitative (required for analyte concentration measurement).Automated optical readers that take images from the test strip and use image processing algorithms to detectthe lines have been used to analyze the results of LFA devices quantitatively. However, these devices are notvery sensitive (i.e. ~%90) as they rely on the optical information derived from reflection of light from the devicesurface, while a large portion of nanoparticles get captured inside the bulk of the strip and become invisible evento scanners or cameras. Their other limitation is their dependency on the use of the colored dyes or fluorescentmolecules that are prone to gradual deterioration under exposure to light.To enhance the existing techniques, we propose to take advantage of the inherent thermal properties of thenanoparticles and to adopt controlled heat stimulation and temperature sensing to detect the lines on LFAdevices in an automatic manner. This technique is accurate and sensitive because the surface temperature willbe a direct function of the accumulation of nanoparticles in the bulk of the membrane that could be correlativelyquantified. It is also label-free as it relies on the thermal properties of nanoparticles themselves and does notrequire the colored reagents or fluorescent tags. By employing these principles, we, in collaboration with thecompany BTNX Inc., will conduct fundamental feasibility studies and develop a reader prototype that will betested on commercially-available single- and multi-test LFA devices. The reader is anticipated to significantlyimprove the detection sensitivities (%100), limits (ng/mL) and dynamic ranges, hence generating more reliableresults for the test users and enabling them to detect analytes easier and earlier in the process and in a noninvasivemanner. Our proposed technique also aims to resolve a critical problem in the existing Point of CareDiagnostics market and offers a new dimension to the LFA devices in terms of their applicability to moresensitive assays, hence enabling BTNX to access new bio-detection markets. Full commercialization of thetechnology with the help and dedication of the company is expected to happen in the next 2-3 years with 1-yearand 5-year anticipated revenues of $100K and $500K, respectively, as well as generation of up to 15 new jobs inOntario.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
471063-2014
Name nom
Rezai, Pouya
Department département
Lassonde School of Engineering
Organization id
38
Institution établissement
York University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2014
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1100
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Health, education and social services
Area of application fr
Santé publique, éducation et services sociaux
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
1
Nb partie
1
Application title
A label-free thermoelectric reader for quantitative interpretation of results from single- and multi-test lateral flow assay devices
Keyword
NSERC
Application summary
The research and development that will be carried out in this project is to resolve an important problem withautomated, quantitative and label-free interpretation of results from Lateral Flow Assay (LFA) devices such asthe home-used pregnancy test strips. LFA devices have gained great popularity for their effective applications inmedical diagnosis, food and beverage manufacturing and water monitoring to name a few. These devices areused to detect the presence of specific analytes such as hormones, toxic chemicals or pathogenicmicroorganisms in many different fluidic specimens. Their working principle is very simple, target analytes getattached to colored nanoparticles via specific capturing reagents coated on the nanoparticles, and thenanoparticles become immobilized along detection line bands on the device as the specimen flows through it.Continuous accumulation of analyte-nanoparticle complexes along the line bands leads to the generation ofvisible lines and qualitative interpretation of results (i.e. yes or no). But, visual interpretation is inaccurate,subjective and most importantly non-quantitative (required for analyte concentration measurement).Automated optical readers that take images from the test strip and use image processing algorithms to detectthe lines have been used to analyze the results of LFA devices quantitatively. However, these devices are notvery sensitive (i.e. ~%90) as they rely on the optical information derived from reflection of light from the devicesurface, while a large portion of nanoparticles get captured inside the bulk of the strip and become invisible evento scanners or cameras. Their other limitation is their dependency on the use of the colored dyes or fluorescentmolecules that are prone to gradual deterioration under exposure to light.To enhance the existing techniques, we propose to take advantage of the inherent thermal properties of thenanoparticles and to adopt controlled heat stimulation and temperature sensing to detect the lines on LFAdevices in an automatic manner. This technique is accurate and sensitive because the surface temperature willbe a direct function of the accumulation of nanoparticles in the bulk of the membrane that could be correlativelyquantified. It is also label-free as it relies on the thermal properties of nanoparticles themselves and does notrequire the colored reagents or fluorescent tags. By employing these principles, we, in collaboration with thecompany BTNX Inc., will conduct fundamental feasibility studies and develop a reader prototype that will betested on commercially-available single- and multi-test LFA devices. The reader is anticipated to significantlyimprove the detection sensitivities (%100), limits (ng/mL) and dynamic ranges, hence generating more reliableresults for the test users and enabling them to detect analytes easier and earlier in the process and in a noninvasivemanner. Our proposed technique also aims to resolve a critical problem in the existing Point of CareDiagnostics market and offers a new dimension to the LFA devices in terms of their applicability to moresensitive assays, hence enabling BTNX to access new bio-detection markets. Full commercialization of thetechnology with the help and dedication of the company is expected to happen in the next 2-3 years with 1-yearand 5-year anticipated revenues of $100K and $500K, respectively, as well as generation of up to 15 new jobs inOntario.