Grant: Engage Grants Program
Ryerson University
$25,000.00
Seismic and fatigue analysis of once-through steam generators
EF 2014-15
Résumé
The behavior of Once-Through Steam Generators (OTSG) is not fully understood under seismic and fatigueloading conditions. Unlike the conventional methods for defining seismic performance factors which iscomplex and mostly based on engineering judgment, this study plans to accurately develop the responsemodification factors under combined static (pushover) and vibratory loads enabling BAH Enterprise Incconducting a safe and reliable design of such operating generators for power plants. The developed parametersand guidelines for a safe structural design of the OTSG and its components undergoing combined loadingconditions will empower BAH to accurately design and assess the integrity and durability of generators andpreventing premature failures in service. The OTSG is designed for a service at temperature of 200°F and assuch, the supports at the base should accommodate thermal growth. For this reason, most of the supports at thebase are free to slide in the longitudinal direction while four braced frames are constructed between theplatform columns and the OTSG to resist seismic and oscillatory forces in the transverse direction.A challenging phase of the proposed research is the complex non-linear structural design and assessment of theOTSG when seismic and fatigue load are coupled. In this stage, the assessment of over-strength and deflectionamplification factors are crucial parameters in design of OTSGs. The structural analysis of generators will beremains a prime concern. Pushover and variable amplitude loading analysis will be performed on the structuralelements by means of numerical FE analysis. The analysis will include assessing non-linear behavior andyielding of steel. Subsequently, using a method recently introduced by FEMA P695 and based on acceptablylow probability of structural collapse, response modification coefficient for the structure will be verified.The development of design guidelines and strategies towards a reliable and risk-free design of the OTSG andits structural elements is an ultimate objective of this study. It is also expected that the mutual collaborationbetween Ryerson University and BAH expands over longer terms through this NSERC engage proposal.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
468702-2014
Name nom
VarvaniFarahani, Ahmad
Department département
Mechanical and Industrial Engineering
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2014
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1206
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Engineering
Area of application fr
Génie
Research subject code
2106
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Stress analysis
Research subject fr
Analyse des contraintes
Partie
1
Nb partie
1
Application title
Seismic and fatigue analysis of once-through steam generators
Keyword
NSERC
Application summary
The behavior of Once-Through Steam Generators (OTSG) is not fully understood under seismic and fatigueloading conditions. Unlike the conventional methods for defining seismic performance factors which iscomplex and mostly based on engineering judgment, this study plans to accurately develop the responsemodification factors under combined static (pushover) and vibratory loads enabling BAH Enterprise Incconducting a safe and reliable design of such operating generators for power plants. The developed parametersand guidelines for a safe structural design of the OTSG and its components undergoing combined loadingconditions will empower BAH to accurately design and assess the integrity and durability of generators andpreventing premature failures in service. The OTSG is designed for a service at temperature of 200°F and assuch, the supports at the base should accommodate thermal growth. For this reason, most of the supports at thebase are free to slide in the longitudinal direction while four braced frames are constructed between theplatform columns and the OTSG to resist seismic and oscillatory forces in the transverse direction.A challenging phase of the proposed research is the complex non-linear structural design and assessment of theOTSG when seismic and fatigue load are coupled. In this stage, the assessment of over-strength and deflectionamplification factors are crucial parameters in design of OTSGs. The structural analysis of generators will beremains a prime concern. Pushover and variable amplitude loading analysis will be performed on the structuralelements by means of numerical FE analysis. The analysis will include assessing non-linear behavior andyielding of steel. Subsequently, using a method recently introduced by FEMA P695 and based on acceptablylow probability of structural collapse, response modification coefficient for the structure will be verified.The development of design guidelines and strategies towards a reliable and risk-free design of the OTSG andits structural elements is an ultimate objective of this study. It is also expected that the mutual collaborationbetween Ryerson University and BAH expands over longer terms through this NSERC engage proposal.