Grant: Discovery Grants Program - Individual

Dalhousie University

$19,000.00

Masonry load bearing walls subject to combined axial load and out-of-plane bending

EF 2010-11

Résumé
As the most commonly used masonry structural components, masonry load bearing walls are frequently subjected to the action of concentric or eccentric gravity loads in combination with lateral loads due to wind or earthquake. The apparent strength of these members is compromised by a secondary moment caused by the gravity load acting through a deflected shape. Due to the low tensile strength of masonry, this situation is further complicated by tension cracking which leads to variations of effective sectional properties over the member height. The reduction in the load carrying capacity of walls due to secondary effects can be significant and the design of these members has to include the secondary moment effects in a rational way. ) While the current Canadian masonry design standard (CSA S304.1-04) recommends a moment magnifier method to account for the secondary moment effect, disparities are often found between the standard suggested equations and experimental results. The complexities associated with both material and geometric nonlinear responses result in a relatively limited application of the existing equations. ) The overall goal of this proposal is to study how various parameters such as physical and mechanical characteristics of masonry and varying loading and boundary conditions affect the strength and behaviour of masonry load bearing walls. This study will be carried out in two phases. In Phase 1, realistically sized wall specimens with various material and geometrical properties will be tested as structural elements under different loading and boundary combinations. In Phase 2, masonry structural wall systems simulating real masonry wall construction will be tested to study the interaction between the masonry wall and its surrounding structural elements. A previously developed analytical model will be refined, verified with the test results and then used in an extensive parametric study. It is anticipated that this in-depth study will further the understanding of the behaviour of masonry load bearing walls and will result in important beneficial refinements to present design procedures in Canada.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Nova Scotia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
261813-2008
Name nom
Liu, Yi
Department département
Civil and Resource Engineering
Organization id
79
Institution établissement
Dalhousie University
Province en
Nova Scotia
Province fr
Nouvelle-Écosse
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2008
Award amount
19000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1061
Committee name en
Civil Engineering - A
Committee name fr
Génie civil - A
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1104
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Structural analysis
Research subject fr
Analyse des structures
Partie
3
Nb partie
5
Application title
Masonry load bearing walls subject to combined axial load and out-of-plane bending
Keyword
NSERC
Application summary
As the most commonly used masonry structural components, masonry load bearing walls are frequently subjected to the action of concentric or eccentric gravity loads in combination with lateral loads due to wind or earthquake. The apparent strength of these members is compromised by a secondary moment caused by the gravity load acting through a deflected shape. Due to the low tensile strength of masonry, this situation is further complicated by tension cracking which leads to variations of effective sectional properties over the member height. The reduction in the load carrying capacity of walls due to secondary effects can be significant and the design of these members has to include the secondary moment effects in a rational way. ) While the current Canadian masonry design standard (CSA S304.1-04) recommends a moment magnifier method to account for the secondary moment effect, disparities are often found between the standard suggested equations and experimental results. The complexities associated with both material and geometric nonlinear responses result in a relatively limited application of the existing equations. ) The overall goal of this proposal is to study how various parameters such as physical and mechanical characteristics of masonry and varying loading and boundary conditions affect the strength and behaviour of masonry load bearing walls. This study will be carried out in two phases. In Phase 1, realistically sized wall specimens with various material and geometrical properties will be tested as structural elements under different loading and boundary combinations. In Phase 2, masonry structural wall systems simulating real masonry wall construction will be tested to study the interaction between the masonry wall and its surrounding structural elements. A previously developed analytical model will be refined, verified with the test results and then used in an extensive parametric study. It is anticipated that this in-depth study will further the understanding of the behaviour of masonry load bearing walls and will result in important beneficial refinements to present design procedures in Canada.