Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of Saskatchewan

$24,000.00

Innovative ion mobility - mass spectrometry workflows for discovering veterinary drug metabolites in tissues and the creation of sensitive methods for their quantification.

EF 2024-25

Résumé
Ensuring food is safe is a public health priority; detection of banned substances are of particular concern as they are often illegally used and can lead to serious adverse health effects in humans, such as cancer. Having accurate and sensitive methods is vital in food safety and consequently, liquid chromatography - mass spectrometry (LC-MS) has become an essential tool due to its high sensitivity and selectivity for analyzing biological samples. The workflow we are developing for analyzing veterinary drug residues involves two main steps; identification and quantification of a suitable drug residue. Within both these steps, biological matrices typically produce very complex mass spectra, which adversely affects selectivity and detection limits. Ion mobility devices help alleviate issues caused by the biological matrix since the separation mechanism of ion mobility differs from both LC and MS. Thus, combining ion mobility with LC-MS leads to a greater separation capacity that simplifies complex analyses. Our workflow employs high-field asymmetric waveform ion mobility spectrometry (FAIMS) in both steps since LC-FAIMS-MS offers very high sensitivity and selectivity. A collaborative effort between Thermo Fisher and my group led to the development of a new FAIMS interface (FAIMS Pro) that addressed initial challenges with FAIMS. However, FAIMS Pro was designed primarily for proteomics where complete ion desolvation readily occurs. For small molecule applications that use high liquid flow rates, a thorough investigation of critical parameters, most notably solvent effects and the integration of gas modifiers, is needed. Developing an optimized FAIMS device for small molecule analysis is a critical step in my proposed research. An investigation of solvent effects combined with the use of gas modifiers in FAIMS, will be used to develop an approach to allow solvated ions to enter FAIMS without adversely affecting sensitivity or robustness. This will be an integral part of a joint effort with Thermo Fisher to redesign the FAIMS Pro device for use specifically with small molecules (sFAIMS) thereby enabling maximal sensitivity by allowing significantly more ions into FAIMS. Integration of sFAIMS into our food safety workflows will improve upon both steps; primarily for overcoming chemical background issues for problematic analytes in quantitative methods, but also in the identification step in using the extra separation capacity to assist the software in extracting suitable drug residues for quantification from complex matrices. In addition to using the workflow for veterinary drug residues in food and tissue, the adaptability makes it amenable to other food safety applications such as food authenticity. Longer term, the workflow can be readily adapted for use in other fields in which high selectivity and sensitivity are required, for example, in identifying and quantifying disease biomarkers in health and medicine.
Programme
Discovery Grants Program - Individual
Emplacement
Saskatchewan, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RGPIN-2021-03293
Name nom
Purves, Randall
Department département
College of Pharmacy and Nutrition
Organization id
16
Institution établissement
University of Saskatchewan
Province en
Saskatchewan
Province fr
Saskatchewan
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2021
Award amount
24000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1504
Committee name en
Chemistry
Committee name fr
Chimie
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
3504
Research subject group en
Analytical chemistry
Research subject group fr
Chimie analytique
Research subject en
Bioanalytical chemistry
Research subject fr
Chimie bioanalytique
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Innovative ion mobility - mass spectrometry workflows for discovering veterinary drug metabolites in tissues and the creation of sensitive methods for their quantification.
Keywords
mass spectrometry; lc-ms; drug residue; faims; quantification; untargeted metabolomics
Application summary
Ensuring food is safe is a public health priority; detection of banned substances are of particular concern as they are often illegally used and can lead to serious adverse health effects in humans, such as cancer. Having accurate and sensitive methods is vital in food safety and consequently, liquid chromatography - mass spectrometry (LC-MS) has become an essential tool due to its high sensitivity and selectivity for analyzing biological samples. The workflow we are developing for analyzing veterinary drug residues involves two main steps; identification and quantification of a suitable drug residue. Within both these steps, biological matrices typically produce very complex mass spectra, which adversely affects selectivity and detection limits. Ion mobility devices help alleviate issues caused by the biological matrix since the separation mechanism of ion mobility differs from both LC and MS. Thus, combining ion mobility with LC-MS leads to a greater separation capacity that simplifies complex analyses. Our workflow employs high-field asymmetric waveform ion mobility spectrometry (FAIMS) in both steps since LC-FAIMS-MS offers very high sensitivity and selectivity. A collaborative effort between Thermo Fisher and my group led to the development of a new FAIMS interface (FAIMS Pro) that addressed initial challenges with FAIMS. However, FAIMS Pro was designed primarily for proteomics where complete ion desolvation readily occurs. For small molecule applications that use high liquid flow rates, a thorough investigation of critical parameters, most notably solvent effects and the integration of gas modifiers, is needed. Developing an optimized FAIMS device for small molecule analysis is a critical step in my proposed research. An investigation of solvent effects combined with the use of gas modifiers in FAIMS, will be used to develop an approach to allow solvated ions to enter FAIMS without adversely affecting sensitivity or robustness. This will be an integral part of a joint effort with Thermo Fisher to redesign the FAIMS Pro device for use specifically with small molecules (sFAIMS) thereby enabling maximal sensitivity by allowing significantly more ions into FAIMS. Integration of sFAIMS into our food safety workflows will improve upon both steps; primarily for overcoming chemical background issues for problematic analytes in quantitative methods, but also in the identification step in using the extra separation capacity to assist the software in extracting suitable drug residues for quantification from complex matrices. In addition to using the workflow for veterinary drug residues in food and tissue, the adaptability makes it amenable to other food safety applications such as food authenticity. Longer term, the workflow can be readily adapted for use in other fields in which high selectivity and sensitivity are required, for example, in identifying and quantifying disease biomarkers in health and medicine.