Grant: Discovery Grants Program - Individual
University of Toronto
$78,000.00
Registration of Endoscopic Optical Information to Volumetric Imaging
EF 2024-25
Résumé
Background: In medical practice, radiological and endosopic/optical imaging each supply complimentary and unique clinical information. Radiological imaging measures bulk tissue properties supplied in 3D spatial coordinates that accurately match those of the physical subject. However, it has insufficient contrast and resolution to identify clinically important mucosal information. Endoscopic optical imaging is invaluable for disease diagnosis, and monitoring treatment response of mucosal anatomy. However, such 2D optical images are spatially disconnected from the subject's 3D spatial coordinates/anatomy or their spatial relationship may be inferred indirectly by the viewer.
From the clinical perspective, what is missing is the anatomical context and relationship of the endoscopy information with respect to the bulk tissue properties supplied by the radiological imaging. For many diseases in hollow organs such as the head and neck, gastrointestinal tract and lung, spatially accurate mapping of endoscopic imaging to bulk radiological imaging would improve diagnosis and treatment.
Attempts to achieve such registration using tracking technologies and computer vision are inaccurate or difficult to implement in hollow organs. True 3D endoscopic imaging for hollow organs remains elusive; especially a version registered to standard radiological imaging that includes subsurface information.
Our long-term vision is the development of a "full" 3D optical/endoscopic imaging package registered to standard radiological imaging. The system will be designed specifically for hollow organs using endoscopic imaging, with the goal of registering both 2D optical images of the surface topology and subsurface information derived from optical tomography to 3D anatomical imaging. The primary objective in this proposal is the technology development and testing of the core technologies, not clinical verification and deployment. We propose two general objectives to achieve this goal. The first objective is 3D endoscopy in which 2D endoscopic images are mapped onto a 3D surface of the object in view. Our goal is registration error between the surface topology and CT images 80%.
On their own, the proposed objectives are unique, offering significant advances in each field: any form of 3D endoscopy for hollow organs will have substantial clinical benefit while increased clinical adoption of optical tomography requires the improved reconstruction accuracy proposed here. Integration of optical and radiological imaging will substantially improve disease diagnosis and treatment planning in hollow organs.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RGPIN-2019-04759
Name nom
Weersink, Robert
Department département
Department of Radiation Oncology
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2019
Award amount
78000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
3114
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Biological and Medical Physics
Research subject fr
Physique biologique et médicale
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Registration of Endoscopic Optical Information to Volumetric Imaging
Keywords
image registration; endoscopy; light modelling; optical imaging; diffuse optical tomography
Application summary
Background: In medical practice, radiological and endosopic/optical imaging each supply complimentary and unique clinical information. Radiological imaging measures bulk tissue properties supplied in 3D spatial coordinates that accurately match those of the physical subject. However, it has insufficient contrast and resolution to identify clinically important mucosal information. Endoscopic optical imaging is invaluable for disease diagnosis, and monitoring treatment response of mucosal anatomy. However, such 2D optical images are spatially disconnected from the subject's 3D spatial coordinates/anatomy or their spatial relationship may be inferred indirectly by the viewer.
From the clinical perspective, what is missing is the anatomical context and relationship of the endoscopy information with respect to the bulk tissue properties supplied by the radiological imaging. For many diseases in hollow organs such as the head and neck, gastrointestinal tract and lung, spatially accurate mapping of endoscopic imaging to bulk radiological imaging would improve diagnosis and treatment.
Attempts to achieve such registration using tracking technologies and computer vision are inaccurate or difficult to implement in hollow organs. True 3D endoscopic imaging for hollow organs remains elusive; especially a version registered to standard radiological imaging that includes subsurface information.
Our long-term vision is the development of a "full" 3D optical/endoscopic imaging package registered to standard radiological imaging. The system will be designed specifically for hollow organs using endoscopic imaging, with the goal of registering both 2D optical images of the surface topology and subsurface information derived from optical tomography to 3D anatomical imaging. The primary objective in this proposal is the technology development and testing of the core technologies, not clinical verification and deployment. We propose two general objectives to achieve this goal. The first objective is 3D endoscopy in which 2D endoscopic images are mapped onto a 3D surface of the object in view. Our goal is registration error between the surface topology and CT images 80%.
On their own, the proposed objectives are unique, offering significant advances in each field: any form of 3D endoscopy for hollow organs will have substantial clinical benefit while increased clinical adoption of optical tomography requires the improved reconstruction accuracy proposed here. Integration of optical and radiological imaging will substantially improve disease diagnosis and treatment planning in hollow organs.