Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

University of Windsor

$24,900.00

Effect of h/t on compressive strength of masonry prisims

EF 2011-12

Résumé
Specified compressive strength of masonry (f'm) is the key technical information required for safe and economical design of masonry structures. The value of f'm is determined by testing masonry prisms to failure by applying compression load as specified in Canadian standard CSA S304.1-04. Prism specimens or simply ""prisms"" simulate a small segment of a masonry wall. This standard recommends using prism specimens with minimum height-to-thickness ratio (h/t) of five for determining the accurate value of f'm though a minimum value for h/t of two is permissible. It is believed that the shorter prisms (h/t < 5) tend to provide an apparent higher compressive strength resulting in an unconservative (unsafe) design. Accordingly, Table D.1 of CSA S304.1-04 recommends correction (reduction) factors when prisms with h/t less than five are used for determining f""m. The correction factors in Table D.1 of this standard are believed to be overly conservative and hence, results in uneconomical design of masonry structure. Therefore, this project will be undertaken to determine more suitable values for the correction (strength reduction) factors when the value of f'm is determined from prisms with h/t less than five. The outcome of this research will minimize conservatism in these correction factors and hence, will provide more economical masonry designs. This research will be completed using laboratory based experimental methods and a large number of prisms will be built and tested in the Structural Engineering laboratory at the University of Windsor. The project is scheduled to be completed in six months from the date of award.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
418219-2011
Name nom
Das, Sreekanta
Department département
Civil and Environmental Engineering
Organization id
37
Institution établissement
University of Windsor
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2011
Award amount
24900
Program id
EGP
Program nane en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
600
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Construction, urban and rural planning
Area of application fr
Construction, urbanisme et aménagement rural
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
1
Nb partie
1
Application title
Effect of h/t on compressive strength of masonry prisims
Keyword
NSERC
Application summary
Specified compressive strength of masonry (f'm) is the key technical information required for safe and economical design of masonry structures. The value of f'm is determined by testing masonry prisms to failure by applying compression load as specified in Canadian standard CSA S304.1-04. Prism specimens or simply ""prisms"" simulate a small segment of a masonry wall. This standard recommends using prism specimens with minimum height-to-thickness ratio (h/t) of five for determining the accurate value of f'm though a minimum value for h/t of two is permissible. It is believed that the shorter prisms (h/t < 5) tend to provide an apparent higher compressive strength resulting in an unconservative (unsafe) design. Accordingly, Table D.1 of CSA S304.1-04 recommends correction (reduction) factors when prisms with h/t less than five are used for determining f""m. The correction factors in Table D.1 of this standard are believed to be overly conservative and hence, results in uneconomical design of masonry structure. Therefore, this project will be undertaken to determine more suitable values for the correction (strength reduction) factors when the value of f'm is determined from prisms with h/t less than five. The outcome of this research will minimize conservatism in these correction factors and hence, will provide more economical masonry designs. This research will be completed using laboratory based experimental methods and a large number of prisms will be built and tested in the Structural Engineering laboratory at the University of Windsor. The project is scheduled to be completed in six months from the date of award.