Grant: Collaborative Research and Development Grants
University of Alberta
$66,460.00
Shear and Sedimentation Test Cell (SSTC) for Measuring the Effect of Mixing on the Performance of Chemical Additives
EF 2011-12
Résumé
The addition of solids or liquids into solutions is a very important issue in many industrial processes, such as oil sands, drinking water treatment, cosmetics and personal care products, and paints and coating. The efficiency of these processes may be improved if an efficient dispersion and dissolution of these additives is achieved. In order to improve process efficiency, the mechanisms involved in the addition of these solids need to be understood. While the mechanisms are studied at the bench scale, these tests do not always represent the real characteristics at the industrial scale. For example, a bench scale test should use 1L or less of sample, while an industrial scale vessel in the oil sands industry may hold 10 000 L or more.
An efficient procedure to scale-up and scale-down these operations is needed because if the additive fails on scale-up the cost is large and the process can fail. Our research group developed the Shear and Sedimentation Test Cell (SSTC) to better represent conditions at the industrial scale. The SSTC has a more uniform intensity of mixing over the volume of the tank, uses a much smaller volume of sample, and allows for the possibility of a sedimentation step after the mixing step with no sample transfer required. The unique geometry of the SSTC allows a more uniform turbulence distribution, which is not obtained in the other bench scale test equipment. This can give accurate and robust design data required for successful scale-up. All of these characteristics are extremely useful for bench scale testing of additives in the oil sands industry, for drinking water tests, for development of personal products, and for fine chemicals such as paints and coatings.
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
419431-2011
Name nom
Kresta, Suzanne
Department département
Chemical and Materials Engineering
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2011
Award amount
66460
Program id
CRDPJ
Program nane en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
300
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy resources (including production, exploration, processing, distribution and use)
Area of application fr
Ressources d'énergie (production, exploration, traitement, distribution et utilisation de l'énergie)
Research subject code
1800
Research subject group en
Chemical engineering
Research subject group fr
Génie chimique
Research subject en
Chemical engineering
Research subject fr
Génie chimique
Partie
1
Nb partie
2
Application title
Shear and Sedimentation Test Cell (SSTC) for Measuring the Effect of Mixing on the Performance of Chemical Additives
Keyword
NSERC
Application summary
The addition of solids or liquids into solutions is a very important issue in many industrial processes, such as oil sands, drinking water treatment, cosmetics and personal care products, and paints and coating. The efficiency of these processes may be improved if an efficient dispersion and dissolution of these additives is achieved. In order to improve process efficiency, the mechanisms involved in the addition of these solids need to be understood. While the mechanisms are studied at the bench scale, these tests do not always represent the real characteristics at the industrial scale. For example, a bench scale test should use 1L or less of sample, while an industrial scale vessel in the oil sands industry may hold 10 000 L or more.
An efficient procedure to scale-up and scale-down these operations is needed because if the additive fails on scale-up the cost is large and the process can fail. Our research group developed the Shear and Sedimentation Test Cell (SSTC) to better represent conditions at the industrial scale. The SSTC has a more uniform intensity of mixing over the volume of the tank, uses a much smaller volume of sample, and allows for the possibility of a sedimentation step after the mixing step with no sample transfer required. The unique geometry of the SSTC allows a more uniform turbulence distribution, which is not obtained in the other bench scale test equipment. This can give accurate and robust design data required for successful scale-up. All of these characteristics are extremely useful for bench scale testing of additives in the oil sands industry, for drinking water tests, for development of personal products, and for fine chemicals such as paints and coatings.