Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

Carleton University

$25,000.00

Robust design and modelling of solar houses: methodology and technologies

EF 2013-14

Résumé
Direct solar gain (AKA passive solar) strategies in houses (detached and row houses) are among the most cost-effective and simplest approaches to significantly reducing total household energy use. They use a combination of large high-performance south-facing windows, thermally-massive materials, and high levels of insulation and air-tightness. However, when designing solar houses using building performance simulation (BPS) many assumptions must be made about occupancy and occupant behaviour (e.g., window openings, electrical appliance use, and heating and cooling setpoints) - despite an [often] high degree of uncertainty. Thus, designers aiming for optimal designs are actually optimizing around a set of assumptions rather than real operating conditions. A greater risk is that the house's performance will be highly-sensitive to the accuracy of the assumptions and that it will under-perform relative to predicted results if and when reality deviates from the assumptions. Rather than attempt to control the the way occupants behave (which has been proven to be very difficult), the proposed research will develop methods for robust solar house design. This entails implementing design features and control strategies that are significantly less sensitive to a range of occupant-related energy use. Monte Carlo analysis methods combined with building performance simulation and a database of probability distributions for all sources of uncertainty will be used to test the robustness of solar designs.Utilizing the robustness framework, the proposed research will develop a multi-zone forced-air system that enables better solar heat gains distributions within a house will be designed. The system will be modelled using BPS and airflow networks to assess energy and thermal comfort performance. A major aspect of this research is focused on assessing the convective heat transfer between charged thermal mass (e.g., a concrete floor warmed by the sun) and the adjacent air. Experimental techniques using a highly-instrumented house will complement modelling approaches.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
418608-2013
Name nom
OBrien, William
Department département
Civil and Environmental Engineering
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
25000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
1
Nb partie
5
Application title
Robust design and modelling of solar houses: methodology and technologies
Keyword
NSERC
Application summary
Direct solar gain (AKA passive solar) strategies in houses (detached and row houses) are among the most cost-effective and simplest approaches to significantly reducing total household energy use. They use a combination of large high-performance south-facing windows, thermally-massive materials, and high levels of insulation and air-tightness. However, when designing solar houses using building performance simulation (BPS) many assumptions must be made about occupancy and occupant behaviour (e.g., window openings, electrical appliance use, and heating and cooling setpoints) - despite an [often] high degree of uncertainty. Thus, designers aiming for optimal designs are actually optimizing around a set of assumptions rather than real operating conditions. A greater risk is that the house's performance will be highly-sensitive to the accuracy of the assumptions and that it will under-perform relative to predicted results if and when reality deviates from the assumptions. Rather than attempt to control the the way occupants behave (which has been proven to be very difficult), the proposed research will develop methods for robust solar house design. This entails implementing design features and control strategies that are significantly less sensitive to a range of occupant-related energy use. Monte Carlo analysis methods combined with building performance simulation and a database of probability distributions for all sources of uncertainty will be used to test the robustness of solar designs.Utilizing the robustness framework, the proposed research will develop a multi-zone forced-air system that enables better solar heat gains distributions within a house will be designed. The system will be modelled using BPS and airflow networks to assess energy and thermal comfort performance. A major aspect of this research is focused on assessing the convective heat transfer between charged thermal mass (e.g., a concrete floor warmed by the sun) and the adjacent air. Experimental techniques using a highly-instrumented house will complement modelling approaches.