Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Alliance Grants

University of Winnipeg

$100,000.00

Rampable Intraoperative Magnetic Resonance Imaging_x000d_ _x000d_

EF 2020-21

Résumé
MRI scanners generate exquisitely detailed images of brain and spinal cord anatomy and pathology. Although an engineering challenge, the placement of MRI systems in the operating room will revolutionize neurosurgical care. The first commercial iMRI systems were developed by GE based on a 0.5 Tesla magnet with Brigham and Women's hospital in Boston. In 1988 a group in Winnipeg (IMRIS) developed an iMRI system based on a 1.5 Tesla magnet which overcame many of the difficult issues discovered with the GE system. The iMRI technology enabled neurosurgeons to improve surgeries and outcomes. Intraoperative MRI has also identified a significant number of patients who harboured unsuspected, residual tumour at the end of surgery, thus sparing them the discomfort and expense of reoperation. The major problem with the IMRIS intraoperative system which is the market leader it was is too expensive. An even more serious problem was that the cost of renovation to the hospital was much more expensive and required operating suites to be closed for months during this renovation. Our new concept is to base the iMRI on a cryogen free magnet which can be ramped to 1 tesla and is stable at this field in 10 minutes. The magnet will be made with Magnesium Diboride (MgB2) which is a high temperature superconducting material. The magnet will be continually connected to a power supply and so will not require to be persistent allowing for the rapid ramp rate. The objective of the new design is to have an intra-operative MRI that take 2 weeks to install in a standard hospital surgical suite which can provide images of the same quality as a 1.5 Tesla commercial MRI on 2012 in the same time. The important research factor being developed in this proposal is to obtain image quality equivalent or better to what was obtained with the 1.5 tesla IMRIS systems. It is well known that the signal to noise ratio (SNR) increases linearly with field strength so a 1 Tesla magnet will have about 60% of the SNR to that of 1.5 Tesla magnet. We will develop RF coils and AI techniques to improve image quality.
Programme
Alliance Grants
Emplacement
Manitoba, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
555261-2020
Name nom
Martin, Melanie
Department département
Physics
Organization id
21
Institution établissement
University of Winnipeg
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2020
Competition year année de concours
2020
Award amount
100000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
Rampable Intraoperative Magnetic Resonance Imaging_x000d_ _x000d_
Keyword
NSERC
Application summary
MRI scanners generate exquisitely detailed images of brain and spinal cord anatomy and pathology. Although an engineering challenge, the placement of MRI systems in the operating room will revolutionize neurosurgical care. The first commercial iMRI systems were developed by GE based on a 0.5 Tesla magnet with Brigham and Women's hospital in Boston. In 1988 a group in Winnipeg (IMRIS) developed an iMRI system based on a 1.5 Tesla magnet which overcame many of the difficult issues discovered with the GE system. The iMRI technology enabled neurosurgeons to improve surgeries and outcomes. Intraoperative MRI has also identified a significant number of patients who harboured unsuspected, residual tumour at the end of surgery, thus sparing them the discomfort and expense of reoperation. The major problem with the IMRIS intraoperative system which is the market leader it was is too expensive. An even more serious problem was that the cost of renovation to the hospital was much more expensive and required operating suites to be closed for months during this renovation. Our new concept is to base the iMRI on a cryogen free magnet which can be ramped to 1 tesla and is stable at this field in 10 minutes. The magnet will be made with Magnesium Diboride (MgB2) which is a high temperature superconducting material. The magnet will be continually connected to a power supply and so will not require to be persistent allowing for the rapid ramp rate. The objective of the new design is to have an intra-operative MRI that take 2 weeks to install in a standard hospital surgical suite which can provide images of the same quality as a 1.5 Tesla commercial MRI on 2012 in the same time. The important research factor being developed in this proposal is to obtain image quality equivalent or better to what was obtained with the 1.5 tesla IMRIS systems. It is well known that the signal to noise ratio (SNR) increases linearly with field strength so a 1 Tesla magnet will have about 60% of the SNR to that of 1.5 Tesla magnet. We will develop RF coils and AI techniques to improve image quality.