Grant: Idea to Innovation
University of British Columbia
$15,000.00
Sample stabilization system for super-resolution microscopy
EF 2015-16
Résumé
Optical microscopy is one of the most widely-used research tools. Because of the diffraction limit, its resolution has been limited to ~250 nm. Breakthroughs made in the past several years have overcome the diffraction barrier. Super-resolution microscopy, such as STORM, PALM, and STED, has enabled researchers to carry out optical imaging with a resolution better than 10 nm. However, one fundamental obstacle all researchers are facing is the inability to hold a sample immobile on the nm-scale during the image acquisition time, typically 5-10 min. Sample drift due to thermal gradients or mechanical motion is easily in the hundreds of nanometers or even microns. This uncertainty in the sample position renders the super-resolution images inaccurate and unrepeatable. Currently no commercial systems are capable of completely resolving this issue. In response to this need, we have developed a 3D microscope stabilization system to eliminate sample drift. Our system limits the 3D drift to less than 1 nm in the x-y plane and 2.5 nm in the z axis. On the basis of our invention, a research paper was published, and a provisional patent application was filed in the USA in February 2015. The goal of this market assessment is to validate the potential market size for the technology, the end-user need, and their willingness/ability to purchase the product.
Programme
Idea to Innovation
Bénéficiaire
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
486707-2015
Name nom
Chou, KengChang
Department département
Chemistry
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
15000
Program id
I2IPJ
Program name en
Idea to Innovation
Program name fr
De l'idée à l'innovation
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
1
Nb partie
1
Application title
Sample stabilization system for super-resolution microscopy
Keyword
NSERC
Application summary
Optical microscopy is one of the most widely-used research tools. Because of the diffraction limit, its resolution has been limited to ~250 nm. Breakthroughs made in the past several years have overcome the diffraction barrier. Super-resolution microscopy, such as STORM, PALM, and STED, has enabled researchers to carry out optical imaging with a resolution better than 10 nm. However, one fundamental obstacle all researchers are facing is the inability to hold a sample immobile on the nm-scale during the image acquisition time, typically 5-10 min. Sample drift due to thermal gradients or mechanical motion is easily in the hundreds of nanometers or even microns. This uncertainty in the sample position renders the super-resolution images inaccurate and unrepeatable. Currently no commercial systems are capable of completely resolving this issue. In response to this need, we have developed a 3D microscope stabilization system to eliminate sample drift. Our system limits the 3D drift to less than 1 nm in the x-y plane and 2.5 nm in the z axis. On the basis of our invention, a research paper was published, and a provisional patent application was filed in the USA in February 2015. The goal of this market assessment is to validate the potential market size for the technology, the end-user need, and their willingness/ability to purchase the product.