Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Research Tools and Instruments

University of Alberta

$84,452.00

High-resolution quantitative fluorescence detection systems

EF 2015-16

Résumé
This RTI funding request is to develop high-resolution fluorescence detection equipment that provides systems for both spatial and temporal resolution of fluorescence detection. The funds will be used to purchase enhancements to existing equipment used for fluorescence detection. First, we will upgrade a spectrofluorometer with a new digital interface, because the analog interface has become unstable, and add a stopped flow apparatus. These upgrades will make the instrument's use much more reliable and enable new types of experiments that require rapid addition of components to reactions and fluorescence detection in real time. The stopped flow accessory is used to rapidly mix small volumes of two (or more) different reagents in a cuvette, quickly stop their flow to the cuvette and monitor the resulting reaction via optical means. Second, we have requested to purchase a 561 nm laser for our Leica Ultraview confocal microscope. The quote is for a diode-pumped solid state laser and installation by the vendor. Diode-pumped lasers are the most reliable and should not require maintenance over the lifetime of the microscope.  The system has a functional 488 nm diode lasers and this second laser would facilitate studies where dual measurements are required (e.g. cellular effects when overexpressing a GFP-tagged protein). Both of these systems are needed to provide a full complement of research tools capable of cross-validating experiments that require high spatial and temporal resolution of fluorescence detection. The Department of Cell Biology actively maintains and develops infrastructure for high-resolutions quantitative fluorescence detection. The application outlines research programs for HQP in the use of this infrastructure for four NSERC funded labs in the department of Cell Biology; the Montpetit, LaPointe, Simmen and Eitzen labs. These labs are actively collaborating in the development of infrastructure to provide high-resolution quantitative fluorescence detection system for their respective research programs. In fact, all NSERC funded labs in Cell Biology (we have 7) fully support this equipment request (no other applications are submitted) and could provide details on how they plan to use the infrastructure. However, due to space limitations we have only provided details of the research program from what we anticipate will be the the four main users. The equipment is, and has always been, available to any user requiring the specified configuration. Indeed, past users have been from many departments in the Faculty of Medicine and Dentistry and the Faculty of Science.
Programme
Research Tools and Instruments
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RTI-2016-00247
Name nom
Eitzen, Gary
Department département
Cell Biology - Cell Biology
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2016
Award amount
84452
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1601
Committee name en
Genes, Cells and Molecules (RTI)
Committee name fr
Gènes, cellules et molécules (OIR)
Area of application code
1201
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Life sciences (including biotechnology)
Area of application fr
Sciences de la vie (y compris biotechnologie)
Research subject code
5111
Research subject group en
Cell biology
Research subject group fr
Biologie cellulaire
Research subject en
Signal transduction
Research subject fr
Transduction de signal
Partie
1
Nb partie
1
Application title
High-resolution quantitative fluorescence detection systems
Keyword
NSERC
Application summary
<p>This RTI funding request is to develop high-resolution fluorescence detection equipment that provides systems for both spatial and temporal resolution of fluorescence detection. The funds will be used to purchase enhancements to existing equipment used for fluorescence detection.</p> <p>First, we will upgrade a spectrofluorometer with a new digital interface, because the analog interface has become unstable, and add a stopped flow apparatus. These upgrades will make the instrument's use much more reliable and enable new types of experiments that require rapid addition of components to reactions and fluorescence detection in real time. The stopped flow accessory is used to rapidly mix small volumes of two (or more) different reagents in a cuvette, quickly stop their flow to the cuvette and monitor the resulting reaction via optical means. </p> <p>Second, we have requested to purchase a 561 nm laser for our Leica Ultraview confocal microscope. The quote is for a diode-pumped solid state laser and installation by the vendor. Diode-pumped lasers are the most reliable and should not require maintenance over the lifetime of the microscope. &nbsp;The system has a functional 488 nm diode lasers and this second laser would facilitate studies where dual measurements are required (e.g. cellular effects when overexpressing a GFP-tagged protein).</p> <p>Both of these systems are needed to provide a full complement of research tools capable of cross-validating experiments that require high spatial and temporal resolution of fluorescence detection. The Department of Cell Biology actively maintains and develops infrastructure for high-resolutions quantitative fluorescence detection. The application outlines research programs for HQP in the use of this infrastructure for four NSERC funded labs in the department of Cell Biology; the Montpetit, LaPointe, Simmen and Eitzen labs. These labs are actively collaborating in the development of infrastructure to provide high-resolution quantitative fluorescence detection system for their respective research programs. In fact, all NSERC funded labs in Cell Biology (we have 7) fully support this equipment request (no other applications are submitted) and could provide details on how they plan to use the infrastructure. However, due to space limitations we have only provided details of the research program from what we anticipate will be the the four main users. The equipment is, and has always been, available to any user requiring the specified configuration. Indeed, past users have been from many departments in the Faculty of Medicine and Dentistry and the Faculty of Science.</p>