Grant: Engage Plus Grants Program
University of Alberta
$12,500.00
Enhancement of hot-cold sensation testing device
EF 2016-17
Résumé
This project is to enhance and build a second generation prototype of a portable hot-cold sensation device. Thisdiagnostic device will be used to test and record a patient's sensitivity to hot and cold sensation on their limbs.The device will be used in multiple settings such as an examination room, care facilities, or therapy clinics. Thetest is a non-invasive procedure. Currently, no such portable electronic device exists. The method to examinehot and cold sensation is not standardized. Some clinics use test tubes filled with warm water or cracked iceand water for testing. Temperatures less than 5 degrees and greater than 45 degrees Celsius elicit painfulresponses so these temperature ranges should be avoided. Typically, clinicians will ask patients to close theireyes and describe the stimulus when they touch their limbs with different test tubes of various temperatures.Sometimes, a tuning fork will be used as a cool object. These techniques are subjective and highly dependentupon the clinician's procedure and the temperature of the test tubes change over time and with use andtherefore, the methods tend to differ between clinics.Clinisys, a company incorporated in Alberta which would like to address these issues by designing andmanufacturing a hot-cold sensation testing device. An NSERC engage grant was funded from January to June2016. Two prototype devices were developed which were able to be set to the requested temperature in a shortperiod of time. However, after the prototype was evaluated by a group of clinicians, they make a list ofrecommendations. First of all, the cold temperature generated from the device was not stable long enough afterthe contact plate touches a person's limb. Secondly, the clinicians would like to see the device completelysealed so that it can have better infection control. Additional features include vibration and visual feedback ona smart phone or a tablet. Also, the device should be able to upload its recorded information to the patient'srecord in real-time. Therefore, the goal of this project is to further research, develop and enhance the hot-coldsensation diagnostic device so that Clinisys can bring it to the market.
Programme
Engage Plus Grants Program
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
505585-2016
Name nom
Lou, Edmond
Department département
Surgery
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2016
Award amount
12500
Program id
EGP2
Program name en
Engage Plus Grants Program
Program name fr
Programme de subvention d'engagement partenarial Plus
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
513
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Electrical and electronic machinery and equipment (including computer hardware)
Area of application fr
Machinerie et équipement électriques et électroniques (y compris matériel informatique)
Research subject code
2506
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electron devices
Research subject fr
Dispositifs électroniques
Partie
1
Nb partie
1
Application title
Enhancement of hot-cold sensation testing device
Keyword
NSERC
Application summary
This project is to enhance and build a second generation prototype of a portable hot-cold sensation device. Thisdiagnostic device will be used to test and record a patient's sensitivity to hot and cold sensation on their limbs.The device will be used in multiple settings such as an examination room, care facilities, or therapy clinics. Thetest is a non-invasive procedure. Currently, no such portable electronic device exists. The method to examinehot and cold sensation is not standardized. Some clinics use test tubes filled with warm water or cracked iceand water for testing. Temperatures less than 5 degrees and greater than 45 degrees Celsius elicit painfulresponses so these temperature ranges should be avoided. Typically, clinicians will ask patients to close theireyes and describe the stimulus when they touch their limbs with different test tubes of various temperatures.Sometimes, a tuning fork will be used as a cool object. These techniques are subjective and highly dependentupon the clinician's procedure and the temperature of the test tubes change over time and with use andtherefore, the methods tend to differ between clinics.Clinisys, a company incorporated in Alberta which would like to address these issues by designing andmanufacturing a hot-cold sensation testing device. An NSERC engage grant was funded from January to June2016. Two prototype devices were developed which were able to be set to the requested temperature in a shortperiod of time. However, after the prototype was evaluated by a group of clinicians, they make a list ofrecommendations. First of all, the cold temperature generated from the device was not stable long enough afterthe contact plate touches a person's limb. Secondly, the clinicians would like to see the device completelysealed so that it can have better infection control. Additional features include vibration and visual feedback ona smart phone or a tablet. Also, the device should be able to upload its recorded information to the patient'srecord in real-time. Therefore, the goal of this project is to further research, develop and enhance the hot-coldsensation diagnostic device so that Clinisys can bring it to the market.