Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

University of Western Ontario

$24,900.00

Assessment of the suitability of an MRI-compatible actuator for use in MR quality assurance phantoms

EF 2012-13

Résumé
Modus Medical Devices Inc. is a Canadian company with a well known international reputation for providing innovative quality assurance tools for advanced radiotherapy. They specialize in the development of phantoms which are used to ensure that radiotherapy systems are providing the correct treatment at the proper location in the patient. Their phantoms can either be static or can be dynamic which mimics patient respiratory motion. While Modus' current focus is on devices servicing radiology employing CT, new systems have been developed in which radiology will be coupled with magnetic-resonance imaging (MRI). They wish to create a new product line which will provide quality assurance phantoms for these new systems. However, their current product offerings are based on traditional electromagnetic-based actuators which cannot be used in the MRI environment. Modus wishes to develop an all new drive system which can fully function in the MRI and has both a linear motion and a rotational motion. The research group at UWO has developed an MRI-compatible actuator with the required modes of motion but because it was required to function with a patient also in the bore of the MRI, its size was minimized and so was its force capacity. To meet the motion requirements set out by Modus, the device will be adapted to improve its force capacity without such a tight restriction on its size. The project will start with establishment of performance requirements by Modus to achieve realistic respiratory motion. Then the design of the actuator will be modified to meet the requirements while still having the flexibility to be used as a test bed for other motions (such as cardiac). The prototype will validated by a series of tests outside and inside of the MRI.
Programme
Engage Grants Program
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
434826-2012
Name nom
Salisbury, Shaun
Department département
Mechanical and Materials Engineering
Organization id
36
Institution établissement
University of Western Ontario
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
24900
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
1
Nb partie
1
Application title
Assessment of the suitability of an MRI-compatible actuator for use in MR quality assurance phantoms
Keyword
NSERC
Application summary
Modus Medical Devices Inc. is a Canadian company with a well known international reputation for providing innovative quality assurance tools for advanced radiotherapy. They specialize in the development of phantoms which are used to ensure that radiotherapy systems are providing the correct treatment at the proper location in the patient. Their phantoms can either be static or can be dynamic which mimics patient respiratory motion. While Modus' current focus is on devices servicing radiology employing CT, new systems have been developed in which radiology will be coupled with magnetic-resonance imaging (MRI). They wish to create a new product line which will provide quality assurance phantoms for these new systems. However, their current product offerings are based on traditional electromagnetic-based actuators which cannot be used in the MRI environment. Modus wishes to develop an all new drive system which can fully function in the MRI and has both a linear motion and a rotational motion. The research group at UWO has developed an MRI-compatible actuator with the required modes of motion but because it was required to function with a patient also in the bore of the MRI, its size was minimized and so was its force capacity. To meet the motion requirements set out by Modus, the device will be adapted to improve its force capacity without such a tight restriction on its size. The project will start with establishment of performance requirements by Modus to achieve realistic respiratory motion. Then the design of the actuator will be modified to meet the requirements while still having the flexibility to be used as a test bed for other motions (such as cardiac). The prototype will validated by a series of tests outside and inside of the MRI.