Grant: Collaborative Research and Development Grants
McMaster University
$64,000.00
Development of a high performance standoff radiation detection system (SORDS)
EF 2016-17
Résumé
The detection of nuclear threat is a critical component of Canada's national security network. Being able to detect small amounts of radiation at large distances is especially important in a wide range of applications including homeland security, customs and border protection, emergency response to nuclear accidents, and military tasks on the battlefield. Tools currently exist but they are sub-optimal. In order to optimally use the manpower and resources currently available for radiological response, a highly sensitive radiation detection device, which can rapidly determine the type and location of the radiation source term from a distant location (~10-50 meters), is desired. The basic requirements for such a device are high sensitivity, high dynamic range, low mass, portable unit with spectrographic capabilities among others. Many of these requirements are shared with radiation technology that is widely used in medical physics imaging applications and as a result, there is an excellent opportunity to capitalize on the decades of operational experience and optimization that has occurred in the medical physics area. Of particular interest is the fact that medical imaging techniques such as Positron Emission Tomography (PET) also require rapid acquisition of spectral and directional photon flux profiles in a confined space. These requirements translate into directional detection capability, high detection cross section to volume ratio, high-count rate capability and energy dispersive measurement, all of which map directly into the basic requirements of an Intelligent Radiation Mapping Device (IRMD). Our goal is to develop a high performance standoff radiation detection system (SORDS) using novel scintillators and silicon photomultipliers (SiPMs). This proposal is being prepared in conjunction with an industrial partner, as well as research scientists at Defence Department so that all parties may capitalize on their respective expertise in the design of the proposed high performance detection system.
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
486453-2015
Name nom
Peng, Hao
Department département
Science, Faculty of
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2015
Award amount
64000
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
2400
Research subject group en
Nuclear engineering
Research subject group fr
Génie nucléaire
Research subject en
Nuclear engineering
Research subject fr
Génie nucléaire
Partie
1
Nb partie
3
Application title
Development of a high performance standoff radiation detection system (SORDS)
Keyword
NSERC
Application summary
The detection of nuclear threat is a critical component of Canada's national security network. Being able to detect small amounts of radiation at large distances is especially important in a wide range of applications including homeland security, customs and border protection, emergency response to nuclear accidents, and military tasks on the battlefield. Tools currently exist but they are sub-optimal. In order to optimally use the manpower and resources currently available for radiological response, a highly sensitive radiation detection device, which can rapidly determine the type and location of the radiation source term from a distant location (~10-50 meters), is desired. The basic requirements for such a device are high sensitivity, high dynamic range, low mass, portable unit with spectrographic capabilities among others. Many of these requirements are shared with radiation technology that is widely used in medical physics imaging applications and as a result, there is an excellent opportunity to capitalize on the decades of operational experience and optimization that has occurred in the medical physics area. Of particular interest is the fact that medical imaging techniques such as Positron Emission Tomography (PET) also require rapid acquisition of spectral and directional photon flux profiles in a confined space. These requirements translate into directional detection capability, high detection cross section to volume ratio, high-count rate capability and energy dispersive measurement, all of which map directly into the basic requirements of an Intelligent Radiation Mapping Device (IRMD). Our goal is to develop a high performance standoff radiation detection system (SORDS) using novel scintillators and silicon photomultipliers (SiPMs). This proposal is being prepared in conjunction with an industrial partner, as well as research scientists at Defence Department so that all parties may capitalize on their respective expertise in the design of the proposed high performance detection system.