Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

Université de Sherbrooke

$78,000.00

Compressive sensing-based sparse transducers for ultrasound imaging

EF 2024-25

Résumé
Ultrasound imaging is used routinely for material testing and for the diagnosis of many diseases. The resolution of ultrasound imaging is determined by various factors, including transducer design and frequency of operation. To maximize resolution, high operating frequencies (> 1 MHz) and multi-element transducers are usually employed, leading to two major limitations: 1) the penetration depth is limited by the large attenuation of the ultrasonic waves in the propagating medium and by the aberration and reverberation associated with the interfaces at high frequencies, 2) the complexity of the signal processing associated with a large number of transducer elements still limits the achievable frame rate for a given image quality. Until now, most of the work conducted has focused on either imaging algorithms or transducers design. A unique combination of enabling technologies will allow a major breakthrough in the penetration depth and frame rate in ultrasound imaging: 1) the imaging algorithm Excitelet, which exploits lower frequency ultrasound and inherently considers a detailed model of the full wave propagation path, 2) compressive sensing algorithms, which exploit diversity in encoded propagation paths, and 3) additive manufacturing technologies, which enable encoding wave propagation paths within metamaterials. The objective of this program is to create a new generation of sparse ultrasound transducer arrays with a low number of elements, for lower signal processing complexity and higher frame rate, and working at low frequency for improved penetration depth, therefore breaking with existing approaches. The arrays will be used for ultrasound imaging of media which can be either engineering materials or biological tissues. Lateral resolution down to 1/30 of the wavelength is sought at large penetration depth and at a frame rate in the order of 1-10 kHz. This research program articulates along three research thrusts, parallel but related: 1) compressive sensing with ultrasound transducers, where the type of waves and frequencies will be used to enrich information encoding, 2) optimization of sparse transducer arrays, where Excitelet will be considered within the optimization process, and 3) metamaterials in ultrasound probe fabrication, where additive manufacturing techniques will be used to fabricate the metamaterials for encoding the information and other components of the probe. In material testing, this work will allow better characterization of damage precursor in advanced materials, such as composite structures (micro-cracks, voids, micro-buckling, local fiber breakage, or local fiber-matrix debonding). In medical diagnosis, this work will contribute to answer an urgent need for fast imaging frame rates and better resolution in both near- and far-field to avoid the risks in the surrounding organs in guided procedures, in addition to extended penetration depth in order to adapt to the increasing proportion of the obese population.
Programme
Discovery Grants Program - Individual
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RGPIN-2020-07053
Name nom
Masson, Patrice
Department département
Génie mécanique - Génie mécanique
Organization id
68
Institution établissement
Université de Sherbrooke
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2020
Award amount
78000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
703
Area of application group en
Transportation systems and services
Area of application group fr
Services et systèmes de transport
Area of application en
Aerospace
Area of application fr
Aérospatial
Research subject code
2109
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical systems and instrumentation
Research subject fr
Instrumentation et systèmes mécaniques
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Compressive sensing-based sparse transducers for ultrasound imaging
Keywords
ultrasound; transducer arrays; piezoelectric; compressive sensing; high-resolution imaging; metamaterials; non-destructive evaluation; medical imaging; frame rate; penetration depth
Application summary
Ultrasound imaging is used routinely for material testing and for the diagnosis of many diseases. The resolution of ultrasound imaging is determined by various factors, including transducer design and frequency of operation. To maximize resolution, high operating frequencies (> 1 MHz) and multi-element transducers are usually employed, leading to two major limitations: 1) the penetration depth is limited by the large attenuation of the ultrasonic waves in the propagating medium and by the aberration and reverberation associated with the interfaces at high frequencies, 2) the complexity of the signal processing associated with a large number of transducer elements still limits the achievable frame rate for a given image quality. Until now, most of the work conducted has focused on either imaging algorithms or transducers design. A unique combination of enabling technologies will allow a major breakthrough in the penetration depth and frame rate in ultrasound imaging: 1) the imaging algorithm Excitelet, which exploits lower frequency ultrasound and inherently considers a detailed model of the full wave propagation path, 2) compressive sensing algorithms, which exploit diversity in encoded propagation paths, and 3) additive manufacturing technologies, which enable encoding wave propagation paths within metamaterials. The objective of this program is to create a new generation of sparse ultrasound transducer arrays with a low number of elements, for lower signal processing complexity and higher frame rate, and working at low frequency for improved penetration depth, therefore breaking with existing approaches. The arrays will be used for ultrasound imaging of media which can be either engineering materials or biological tissues. Lateral resolution down to 1/30 of the wavelength is sought at large penetration depth and at a frame rate in the order of 1-10 kHz. This research program articulates along three research thrusts, parallel but related: 1) compressive sensing with ultrasound transducers, where the type of waves and frequencies will be used to enrich information encoding, 2) optimization of sparse transducer arrays, where Excitelet will be considered within the optimization process, and 3) metamaterials in ultrasound probe fabrication, where additive manufacturing techniques will be used to fabricate the metamaterials for encoding the information and other components of the probe. In material testing, this work will allow better characterization of damage precursor in advanced materials, such as composite structures (micro-cracks, voids, micro-buckling, local fiber breakage, or local fiber-matrix debonding). In medical diagnosis, this work will contribute to answer an urgent need for fast imaging frame rates and better resolution in both near- and far-field to avoid the risks in the surrounding organs in guided procedures, in addition to extended penetration depth in order to adapt to the increasing proportion of the obese population.