$25,000.00

Analyses of nanofilter fouling in potable water treatment

EF 2011-12

Résumé
The province of Manitoba has many lime/soda water treatment plants unable to meet the latest provincial quality standard for chlorine disinfection by-products - trihalomethanes (THMs). Many municipalities are exploring advanced water treatment processes such as membrane treatment as an alternative to the conventional lime/softening process. Dual membrane plants using ultrafiltration and nanofiltration (NF) are replacing conventional coagulation/settling and lime/soda softening processes. Unfortunately typical surface water sources in Manitoba contain major membrane foulants in relatively high concentrations, specifically Dissolved Organic Carbon (DOC) and hardness. Consequently fouling control is of utmost interest to designers and operators of dual membrane plants operating in Manitoba. We propose to study the mechanism for NF membrane fouling. Control of membrane fouling allows for longer filtration runs and for less water to be rejected, which is directly related to the operating cost of the plant. The results of this research may indicate whether other water supply systems could consider membrane filtration as an option to meet stringent water quality regulations. The number of membrane water treatment plant in Canada is growing. The particular fouling mechanisms that these membrane plants experience depend very much on the quality of the local water, yet few local experts are able to solve this problem. Many Canadian utilities consult with a U.S. company on the methods to reduce membrane fouling. This research will train Canadian experts on fouling of membranes operating on waters typical in Canadian Prairies. Associated Engineering, the partner on this NSERC Engage application, will provide training on detailed design of membrane filtration plant. This will result in significant savings to the municipalities and water co-operatives, as well as provide highly qualified personnel for the Canadian consulting industry.
Programme
Engage Grants Program
Emplacement
Manitoba, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
428304-2011
Name nom
Gorczyca, Beata
Department département
Civil Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2011
Award amount
25000
Program id
EGP
Program nane en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
901
Area of application group en
Commercial services
Area of application group fr
Services commerciaux
Area of application en
Sanitary engineering
Area of application fr
Génie sanitaire
Research subject code
1501
Research subject group en
Environmental engineering
Research subject group fr
Génie de l'environnement
Research subject en
Water quality, pollution
Research subject fr
Qualité de l'eau, pollution
Partie
1
Nb partie
1
Application title
Analyses of nanofilter fouling in potable water treatment
Keyword
NSERC
Application summary
The province of Manitoba has many lime/soda water treatment plants unable to meet the latest provincial quality standard for chlorine disinfection by-products - trihalomethanes (THMs). Many municipalities are exploring advanced water treatment processes such as membrane treatment as an alternative to the conventional lime/softening process. Dual membrane plants using ultrafiltration and nanofiltration (NF) are replacing conventional coagulation/settling and lime/soda softening processes. Unfortunately typical surface water sources in Manitoba contain major membrane foulants in relatively high concentrations, specifically Dissolved Organic Carbon (DOC) and hardness. Consequently fouling control is of utmost interest to designers and operators of dual membrane plants operating in Manitoba. We propose to study the mechanism for NF membrane fouling. Control of membrane fouling allows for longer filtration runs and for less water to be rejected, which is directly related to the operating cost of the plant. The results of this research may indicate whether other water supply systems could consider membrane filtration as an option to meet stringent water quality regulations. The number of membrane water treatment plant in Canada is growing. The particular fouling mechanisms that these membrane plants experience depend very much on the quality of the local water, yet few local experts are able to solve this problem. Many Canadian utilities consult with a U.S. company on the methods to reduce membrane fouling. This research will train Canadian experts on fouling of membranes operating on waters typical in Canadian Prairies. Associated Engineering, the partner on this NSERC Engage application, will provide training on detailed design of membrane filtration plant. This will result in significant savings to the municipalities and water co-operatives, as well as provide highly qualified personnel for the Canadian consulting industry.