Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

Dalhousie University

$25,000.00

Pulsed water jet treatments of the surfaces of metal alloys for biomedical applications

EF 2015-16

Résumé
Each year, over 100,000 Canadians require knee or hip replacement. Current technology uses a titanium alloy to attach the implant to the bone, but problems arise at the interface that could be solved with pulsed water jet (PWJ) technology developed at VLN Advanced Technologies Inc. The surface of the alloy is typically roughened by grit blasting with aluminum oxide particles to promote cell growth on the device. However, the particles get imbedded into the titanium surface. Once inside the patient, the particles can become dislodged and lead to cell death in the surrounding tissue and the loosening of the implant, the leading cause for revision surgery. In contrast, pulsed water jets use ultrasound to break a continuous water stream into a series of high speed pulses that create mechanical erosion by cyclic loading of the target without embedding any foreign material. Together with VLN, we will develop a cost effective way of using PWJs to eliminate the need for grit blasting and create a better biocompatible surface. For good adhesion of a titanium implant in bone, the medical implant needs to have surface features with sizes that span the micron scale down to the nano-scale in order to mimic the surrounding biological textures. Metallurgical alloys that naturally phase separate into two components create patterns in their grain structure with multi-length scale features that can imitate those of biological systems. Surgical titanium alloy separates in to a stronger and weaker component. We will design the techniques to mechanically etch away the weaker component with pulsed water jets and leave behind a rough surface with features on the micron- and nano-length scales. The physical structure, chemistry and mechanical properties of the treated surfaces will be characterized with a suite of tools at Dalhousie University to identify the optimal PWJ parameters. Finally we will explore the possibility of engineering the surface morphology by modifying the grain structure in titanium alloys currently being developed at Dalhousie.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Nova Scotia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
484151-2015
Name nom
Monchesky, Theodore
Department département
Physics and Atmospheric Science
Organization id
79
Institution établissement
Dalhousie University
Province en
Nova Scotia
Province fr
Nouvelle-Écosse
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1551
Committee name en
Atlantic Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Atlantique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2001
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials structure, properties and testing
Research subject fr
Structure, propriétés et essais des matériaux
Partie
1
Nb partie
1
Application title
Pulsed water jet treatments of the surfaces of metal alloys for biomedical applications
Keyword
NSERC
Application summary
Each year, over 100,000 Canadians require knee or hip replacement. Current technology uses a titanium alloy to attach the implant to the bone, but problems arise at the interface that could be solved with pulsed water jet (PWJ) technology developed at VLN Advanced Technologies Inc. The surface of the alloy is typically roughened by grit blasting with aluminum oxide particles to promote cell growth on the device. However, the particles get imbedded into the titanium surface. Once inside the patient, the particles can become dislodged and lead to cell death in the surrounding tissue and the loosening of the implant, the leading cause for revision surgery. In contrast, pulsed water jets use ultrasound to break a continuous water stream into a series of high speed pulses that create mechanical erosion by cyclic loading of the target without embedding any foreign material. Together with VLN, we will develop a cost effective way of using PWJs to eliminate the need for grit blasting and create a better biocompatible surface. For good adhesion of a titanium implant in bone, the medical implant needs to have surface features with sizes that span the micron scale down to the nano-scale in order to mimic the surrounding biological textures. Metallurgical alloys that naturally phase separate into two components create patterns in their grain structure with multi-length scale features that can imitate those of biological systems. Surgical titanium alloy separates in to a stronger and weaker component. We will design the techniques to mechanically etch away the weaker component with pulsed water jets and leave behind a rough surface with features on the micron- and nano-length scales. The physical structure, chemistry and mechanical properties of the treated surfaces will be characterized with a suite of tools at Dalhousie University to identify the optimal PWJ parameters. Finally we will explore the possibility of engineering the surface morphology by modifying the grain structure in titanium alloys currently being developed at Dalhousie.