Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Alliance Grants

The University of British Columbia

$25,000.00

New Muscle: Development of an electroactive ionic polymer coiled actuator

EF 2023-24

Résumé
Electroactive polymers, a form of 'artificial muscle', are materials that reversibly contract and expand in response to electrical input energy. There has been significant research on artificial muscles over the past 25 years, motivated by the lack of an actuator that can match muscle. This lack of a muscle-like actuator has impeded development of robots with animal-like agility and dexterity, and, since the same basic molecular mechanisms that drive muscle are effective from the sub-micrometer/micro-organism level, to the meter/blue whale scale, it has affected the ability to replicate the locomotion and activity of life over more than 6 orders of magnitude in length, and eighteen in volume. We propose a new artificial muscle design. It is based on a heat driven artificial muscle that can outperform muscle in many aspects, first described in 2014. The collaborators on this grant have both made important contributions to the understanding, development and application of this technology. An important limitation however, is the need to generate about 100 times more thermal energy to create the actuation than is produced in mechanical output. The current proposal aims to develop an actuator that incorporates low voltage ionic polymers that are now integrated into the twisted, coiled structure of the 2014 artificial muscle. The coiled structure magnifies the small strains of the polymer materials into muscle competitive large strains of the actuator. This will allow actuators to be driven by electrical input energy that is recoverable, and to operate at low voltages (<3 V). Our aim is to demonstrate the feasibility of this new artificial muscle, setting the stage for a new variant of artificial muscle that allows designers to create more life-like devices, broadening the capabilities artificial devices.
Programme
Alliance Grants
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
588221-2023
Name nom
Madden, John JDW
Department département
Electrical and Computer Engineering
Organization id
2
Institution établissement
The University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2023
Competition year année de concours
2023
Award amount
25000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1101
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Human health (including medically-related psychological research)
Area of application fr
Santé publique (y compris recherche psychologique liée à la médecine)
Research subject code
2500
Research subject group en
Electrical and electronic engineering
Research subject group fr
Electrical and electronic engineering
Research subject en
Génie électrique et électronique
Research subject fr
Génie électrique et électronique
Application title
New Muscle: Development of an electroactive ionic polymer coiled actuator
Keyword
actuator; artificial muscle; human asist device; motor; robotics
Application summary
Electroactive polymers, a form of 'artificial muscle', are materials that reversibly contract and expand in response to electrical input energy. There has been significant research on artificial muscles over the past 25 years, motivated by the lack of an actuator that can match muscle. This lack of a muscle-like actuator has impeded development of robots with animal-like agility and dexterity, and, since the same basic molecular mechanisms that drive muscle are effective from the sub-micrometer/micro-organism level, to the meter/blue whale scale, it has affected the ability to replicate the locomotion and activity of life over more than 6 orders of magnitude in length, and eighteen in volume. We propose a new artificial muscle design. It is based on a heat driven artificial muscle that can outperform muscle in many aspects, first described in 2014. The collaborators on this grant have both made important contributions to the understanding, development and application of this technology. An important limitation however, is the need to generate about 100 times more thermal energy to create the actuation than is produced in mechanical output. The current proposal aims to develop an actuator that incorporates low voltage ionic polymers that are now integrated into the twisted, coiled structure of the 2014 artificial muscle. The coiled structure magnifies the small strains of the polymer materials into muscle competitive large strains of the actuator. This will allow actuators to be driven by electrical input energy that is recoverable, and to operate at low voltages (<3 V). Our aim is to demonstrate the feasibility of this new artificial muscle, setting the stage for a new variant of artificial muscle that allows designers to create more life-like devices, broadening the capabilities artificial devices.