Grant: Engage Grants Program
University of Toronto
$25,000.00
Seismic Loss Estimation of Modular Steel Buildings****
EF 2018-19
Résumé
Due to its high strength to weight ratio steel is preferred as the construction material for high rise buildings. During the traditional construction of steel buildings the assembly of all the structural and non-structural components is done on the construction site. On the other hand, modular construction is a relatively new construction technique for steel structures where volumetric modules are fully constructed and finished in a factory, and they are assembled on-site to form a permanent building. This method has gained popularity due to reduced construction time and material waste, and increased quality. The application of modular construction for high-rise buildings is relatively recent around the world; and in Canada the current application of modular steel construction mainly consists of structures that are not more than three-stories in height. High-rise buildings are sensitive to earthquakes due to increased lateral load demand and their ductility and overstrength factors - key parameters for seismic design - depend on the building height. As the height of the modular steel building increases both the reserve of strength and ductility decrease. In the current version of the National Building Code of Canada, these factors are defined according to the seismic force resisting system only. The lack of understanding of the correlation between these two factors and the building height could lead to inadequate designs of high-rise modular steel buildings. Through detailed nonlinear static and dynamic analyses and by developing seismic loss estimation relationships, the proposed research will investigate the key seismic design parameters specifically for modular steel buildings. By combining the design experience of the industry partner and the expertise of University of Toronto's research team in advanced simulation and earthquake engineering, the results of this collaborative research will yield significant benefits for the Canadian modular construction sector.*
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
535754-2018
Name nom
Mercan, Oya
Department département
Civil Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2018
Competition year année de concours
2018
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
1
Nb partie
1
Application title
Seismic Loss Estimation of Modular Steel Buildings****
Keyword
NSERC
Application summary
Due to its high strength to weight ratio steel is preferred as the construction material for high rise buildings. During the traditional construction of steel buildings the assembly of all the structural and non-structural components is done on the construction site. On the other hand, modular construction is a relatively new construction technique for steel structures where volumetric modules are fully constructed and finished in a factory, and they are assembled on-site to form a permanent building. This method has gained popularity due to reduced construction time and material waste, and increased quality. The application of modular construction for high-rise buildings is relatively recent around the world; and in Canada the current application of modular steel construction mainly consists of structures that are not more than three-stories in height. High-rise buildings are sensitive to earthquakes due to increased lateral load demand and their ductility and overstrength factors - key parameters for seismic design - depend on the building height. As the height of the modular steel building increases both the reserve of strength and ductility decrease. In the current version of the National Building Code of Canada, these factors are defined according to the seismic force resisting system only. The lack of understanding of the correlation between these two factors and the building height could lead to inadequate designs of high-rise modular steel buildings. Through detailed nonlinear static and dynamic analyses and by developing seismic loss estimation relationships, the proposed research will investigate the key seismic design parameters specifically for modular steel buildings. By combining the design experience of the industry partner and the expertise of University of Toronto's research team in advanced simulation and earthquake engineering, the results of this collaborative research will yield significant benefits for the Canadian modular construction sector.*