Grant: Engage Grants Program
University of Waterloo
$25,000.00
Punching shear in reinforced concrete slabs supported on walls and long columns.
EF 2016-17
Résumé
Proper design and reinforcing for punching shear of flat concrete slabs is essential for safety and robustness of structures because punching shear failures are brittle and catastrophic. Typically punching shear has been investigated for flat slab on columns where the transition between one-way beam shear and two-way punching shear is clearly defined. However, when the slab is supported on a long wall, the end of the wall is also subject to two-way shear creating punching shear issue. Punching shear at the ends of long walls is not specifically addressed in the codes of practice. Blackwell Structural Engineers routinely encounter these types of connections and the lack of clear guidelines results in a time-consuming design process. Uncertainty in the accuracy of analysis results could also potentially result in unsafe structures since no rational and comprehensive research on the topic has been done.The work proposed herein will be done by employing nonlinear finite element analysis (FEA) for analyzing cases of reinforced concrete slabs supported on different geometries of walls. Calibration of the FEA is done on available typical tests and then the calibrated model is used to investigate non-typical cases. The geometry (slab thickness, test setup) and materials characteristics (concrete strength, aggregate size) of the previous calibration tests performed at the University of Waterloo will be used first. The analysis will continue by extending current FEA analyses to the specific problem of slabs supported by long columns and walls. Slabs with and without shear reinforcement will be analyzed. Direct comparisons of the punching shear scenarios for the same-type slabs supported on a rectangular column and on a wall will allow to assess if the current code design approaches provide rational guidelines. The work will then continue to analyze real cases of concrete slabs supported on walls as specified by the industrial partner from their consulting practice.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
493720-2015
Name nom
Polak, Maria
Department département
Civil & Environmental Engineering
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2015
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1104
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Structural analysis
Research subject fr
Analyse des structures
Partie
1
Nb partie
1
Application title
Punching shear in reinforced concrete slabs supported on walls and long columns.
Keyword
NSERC
Application summary
Proper design and reinforcing for punching shear of flat concrete slabs is essential for safety and robustness of structures because punching shear failures are brittle and catastrophic. Typically punching shear has been investigated for flat slab on columns where the transition between one-way beam shear and two-way punching shear is clearly defined. However, when the slab is supported on a long wall, the end of the wall is also subject to two-way shear creating punching shear issue. Punching shear at the ends of long walls is not specifically addressed in the codes of practice. Blackwell Structural Engineers routinely encounter these types of connections and the lack of clear guidelines results in a time-consuming design process. Uncertainty in the accuracy of analysis results could also potentially result in unsafe structures since no rational and comprehensive research on the topic has been done.The work proposed herein will be done by employing nonlinear finite element analysis (FEA) for analyzing cases of reinforced concrete slabs supported on different geometries of walls. Calibration of the FEA is done on available typical tests and then the calibrated model is used to investigate non-typical cases. The geometry (slab thickness, test setup) and materials characteristics (concrete strength, aggregate size) of the previous calibration tests performed at the University of Waterloo will be used first. The analysis will continue by extending current FEA analyses to the specific problem of slabs supported by long columns and walls. Slabs with and without shear reinforcement will be analyzed. Direct comparisons of the punching shear scenarios for the same-type slabs supported on a rectangular column and on a wall will allow to assess if the current code design approaches provide rational guidelines. The work will then continue to analyze real cases of concrete slabs supported on walls as specified by the industrial partner from their consulting practice.