Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Idea to Innovation

University of Toronto

$149,000.00

Development and validation of high-capacity resilient outrigger damping system for high-rise buildings

EF 2016-17

Résumé
Viscoelastic Coupling Dampers are used to replace traditional reinforced concrete core beams in coupled wall configurations or installed within outrigger wall systems. Although the development work that has taken place to date has validated the VCD for use in core walls which is typical of buildings up to approximately 250 meters, in order to bring the VCD to its full-potential, it is required to develop, test and validate the VCD with special ductile yielding fuses and lock-up mechanisms in outrigger configurations that are used for super-tall and mega-tall towers. Dynamic real-time full-scale testing of VCDs in an outrigger configuration presents a particular challenge because the damper size is roughly double the size and the dampers are subjected to loads on the order of 3 times larger in certain cases than previously tested VCDs. A further challenge is that the connecting elements of the VCDs to the Reinforced Concrete structure also increase in size and force demands and require special detailing to achieve the required stiffness, strength and especially ductility. The VCD technology also includes a lock-up system that allows the device to respond in the viscoelastic range for all wind loading and low amplitude seismic loading but ensures a reliable yielding mechanism in the connecting steel elements for extreme rare earthquake loading. The proposed research programme will bridge this gap through extensive full-scale dynamic testing of large-capacity VCDs designed for outrigger configurations and complete the technological development that is required for the outrigger configuration with lockup and ductile detailing to be used by engineers in their super-tall and mega-tall building designs. In addition, real conventional and damped high-rise structures will be monitored to provide in-situ data on their dynamic properties, including the levels of inherent damping, and to confirm commonly used modeling assumptions for such buildings.
Programme
Idea to Innovation
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
500184-2016
Name nom
Christopoulos, Constantin
Department département
Civil Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2016
Award amount
149000
Program id
I2IPJ
Program name en
Idea to Innovation
Program name fr
De l'idée à l'innovation
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1100
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Structural engineering
Research subject fr
Génie des structures
Partie
1
Nb partie
2
Application title
Development and validation of high-capacity resilient outrigger damping system for high-rise buildings
Keyword
NSERC
Application summary
Viscoelastic Coupling Dampers are used to replace traditional reinforced concrete core beams in coupled wall configurations or installed within outrigger wall systems. Although the development work that has taken place to date has validated the VCD for use in core walls which is typical of buildings up to approximately 250 meters, in order to bring the VCD to its full-potential, it is required to develop, test and validate the VCD with special ductile yielding fuses and lock-up mechanisms in outrigger configurations that are used for super-tall and mega-tall towers. Dynamic real-time full-scale testing of VCDs in an outrigger configuration presents a particular challenge because the damper size is roughly double the size and the dampers are subjected to loads on the order of 3 times larger in certain cases than previously tested VCDs. A further challenge is that the connecting elements of the VCDs to the Reinforced Concrete structure also increase in size and force demands and require special detailing to achieve the required stiffness, strength and especially ductility. The VCD technology also includes a lock-up system that allows the device to respond in the viscoelastic range for all wind loading and low amplitude seismic loading but ensures a reliable yielding mechanism in the connecting steel elements for extreme rare earthquake loading. The proposed research programme will bridge this gap through extensive full-scale dynamic testing of large-capacity VCDs designed for outrigger configurations and complete the technological development that is required for the outrigger configuration with lockup and ductile detailing to be used by engineers in their super-tall and mega-tall building designs. In addition, real conventional and damped high-rise structures will be monitored to provide in-situ data on their dynamic properties, including the levels of inherent damping, and to confirm commonly used modeling assumptions for such buildings.