Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Master's Award: Canada Graduate Scholarships

University of Toronto

$17,500.00

In-Vivo Measurement of Local SAR and Temperature Increases Using MR Thermometry and EPT

EF 2017-18

Résumé
The development of magnetic resonance imaging (MRI) technology has become a widely used tool for non-invasive imaging of the human body. An emerging MRI design takes advantage of shorter radiofrequency (RF) wavelengths by using a 7 T ultra-high field (UHF) for the main magnetic field. The UHF MRI designs have been shown to have increased resolution, sensitivity, and signal-to-noise ratio than lower 1.5 T or 3 T MRI systems. However, due to the high static magnetic field and higher frequency RF pulses, there are safety concerns with use of UHF MRI due to potential heating of tissue. Based on these safety concerns measurements of local power deposited into the body are necessary. Currently, only whole-body estimates of power deposited into a patient are measured, but for patients with implants, like deep brain stimulation implants where MRI imaging is needed for post-treatment analysis, the whole-body estimates do not accurately predict local temperature increases. This work will determine ways to measure local power being deposited a patient by using parallel transmission coils. Temperature measurements will then be estimated and compared against temperature measurements using a technique known as MR thermometry. This will allow for accurate measurements of local temperature increases in a patient in a UHF MRI in real-time during an imaging scan.
Programme
Master's Award: Canada Graduate Scholarships
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
CIHR Funding Decisions Database

Tel que publié

Id
386383
Name
Klein Geoffrey
Region
Ontario
Country
Canada
Orgtype
Institution Paid; Research Institution
Prcname2
Special Cases - Awards Programs
Projecttitle
In-Vivo Measurement of Local SAR and Temperature Increases Using MR Thermometry and EPT
Programtype2
Studentship Programs
Orgnameinp2
University of Toronto
Cihramount2
$17,500
Cihrequipment2
$0
Programname2
Master's Award: Canada Graduate Scholarships
Keyworddelim
Mri; Ultra-High Field
Abstract
The development of magnetic resonance imaging (MRI) technology has become a widely used tool for non-invasive imaging of the human body. An emerging MRI design takes advantage of shorter radiofrequency (RF) wavelengths by using a 7 T ultra-high field (UHF) for the main magnetic field. The UHF MRI designs have been shown to have increased resolution, sensitivity, and signal-to-noise ratio than lower 1.5 T or 3 T MRI systems. However, due to the high static magnetic field and higher frequency RF pulses, there are safety concerns with use of UHF MRI due to potential heating of tissue. Based on these safety concerns measurements of local power deposited into the body are necessary. Currently, only whole-body estimates of power deposited into a patient are measured, but for patients with implants, like deep brain stimulation implants where MRI imaging is needed for post-treatment analysis, the whole-body estimates do not accurately predict local temperature increases. This work will determine ways to measure local power being deposited a patient by using parallel transmission coils. Temperature measurements will then be estimated and compared against temperature measurements using a technique known as MR thermometry. This will allow for accurate measurements of local temperature increases in a patient in a UHF MRI in real-time during an imaging scan.
Competitiondate
201712
Approvedterm2
1 yr 0 mth
Pinamesdelim
Klein, Geoffrey
Approvedterm
1 an 0 mois
Cihrcontribution2
~ $17,500~ $0~