Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

McMaster University

$40,000.00

Advanced neutron and gamma-ray detection

EF 2016-17

Résumé
There has been great progress in neutron and gamma-ray radiation detection in the last decades. In neutron detection, many efforts geared for detecting weak neutron fields have been attempted to address the current issues in neutron detection. In gamma-ray detection, new gamma-ray detectors were developed, which offer excellent energy resolution over the traditional gamma-ray detectors. In spite of this progress and new attempts, there are still fundamental limitations in neutron and gamma-ray detection, particularly for weak neutron and intense gamma-ray fields. In this Discovery research, in order to address these limitations, my research group aims to develop advanced radiation detectors and signal processing systems. Currently, the most critical issue in neutron detection is to find a detection technique alternative to the 3He gaseous neutron counter, the most popular detector type when a high efficiency is desired. However, the 3He supply is currently in great shortage while 3He demand keeps increasing rapidly, which has led to an unsustainable situation. Inspired by our THick Gas Electron Multiplier (THGEM) detector technology, my group aims to design and build a new neutron detector to replace 3He counters. Another main objective of the proposed research is to develop a new signal processing system for high count rate gamma-ray spectrometry. In high counting rates, the average time interval between detected events is very short and multiple pulses can overlap each other, which leads to distortion in pulse height. To date, these pile-up pulses have had to be discarded although they are valid detection events. In principle, the best solution for this problem is to deconvolute the pile-up pulses in real time, but no successful methods have yet been developed for the most famous type of the gamma-ray detector, although there have been a few attempts. My group aims to develop a fast and efficient signal processing system to address this challenge. A major outcome of this Discovery research is a new neutron detector alternative to 3He counters. The detector is expected to be a promising candidate for replacing 3He counters for all areas from the fundamental physics to nuclear industries and the border screening. Another major outcome of this research is a pulse pile-up deconvolution system, which will revolutionize the current radiation signal processing capability for the Canadian nuclear physics community and Canadian nuclear industries.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RGPIN-2016-04516
Name nom
Byun, SooHyun
Department département
Medical Physics & Applied Radiation Sciences - Medical Physics & Applied Radiati
Organization id
27
Institution établissement
McMaster University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2016
Award amount
40000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
302
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Nuclear energy
Area of application fr
Énergie nucléaire
Research subject code
3102
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Nuclear physics
Research subject fr
Physique nucléaire
Partie
1
Nb partie
5
Application title
Advanced neutron and gamma-ray detection
Keyword
NSERC
Application summary
There has been great progress in neutron and gamma-ray radiation detection in the last decades. In neutron detection, many efforts geared for detecting weak neutron fields have been attempted to address the current issues in neutron detection. In gamma-ray detection, new gamma-ray detectors were developed, which offer excellent energy resolution over the traditional gamma-ray detectors. In spite of this progress and new attempts, there are still fundamental limitations in neutron and gamma-ray detection, particularly for weak neutron and intense gamma-ray fields. In this Discovery research, in order to address these limitations, my research group aims to develop advanced radiation detectors and signal processing systems. Currently, the most critical issue in neutron detection is to find a detection technique alternative to the 3He gaseous neutron counter, the most popular detector type when a high efficiency is desired. However, the 3He supply is currently in great shortage while 3He demand keeps increasing rapidly, which has led to an unsustainable situation. Inspired by our THick Gas Electron Multiplier (THGEM) detector technology, my group aims to design and build a new neutron detector to replace 3He counters. Another main objective of the proposed research is to develop a new signal processing system for high count rate gamma-ray spectrometry. In high counting rates, the average time interval between detected events is very short and multiple pulses can overlap each other, which leads to distortion in pulse height. To date, these pile-up pulses have had to be discarded although they are valid detection events. In principle, the best solution for this problem is to deconvolute the pile-up pulses in real time, but no successful methods have yet been developed for the most famous type of the gamma-ray detector, although there have been a few attempts. My group aims to develop a fast and efficient signal processing system to address this challenge. A major outcome of this Discovery research is a new neutron detector alternative to 3He counters. The detector is expected to be a promising candidate for replacing 3He counters for all areas from the fundamental physics to nuclear industries and the border screening. Another major outcome of this research is a pulse pile-up deconvolution system, which will revolutionize the current radiation signal processing capability for the Canadian nuclear physics community and Canadian nuclear industries.