Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

University of Toronto

$24,950.00

Ultrasonic phantom materials for equipment calibration

EF 2015-16

Résumé
Users of ultrasonic scanning systems for high frequency biomedical research require ""phantoms"" made of tissue-mimicking materials in order to calibrate the ultrasonic signals and understand the images acquired by the equipment. Without such phantoms, it is not practical to compare experimental results from different laboratories, or to transfer research findings to a clinical setting. Our objective in this project is to develop a new stable phantom material that has a similar response to ultrasound to that of human tissue at frequencies up to 50 MHz. Once this tissue-mimicking material has been developed, it can also be used by our industrial partner FujiFilmVisualSonics to assemble more complex phantoms that can be used for technician training or interpretation of ultrasonic images. The key challenge in this project is to attain appropriate levels of ultrasonic velocity, attenuation, and density to mimic human tissue - all within a single, stable material. By adjusting the amount of cross-linking of polymer chains during the manufacturing response, we intend to adjust the ultrasonic damping to bring it in line with almost any specified biomedical tissue. A process to embed thin tungsten wire filaments and nylon fibers in straight lines inside the phantom material for equipment calibration purposes is also being developed; these targets will provide a suitable calibration test for equipment to confirm that its sensitivity and resolution meet required specifications. The VisualSonics equipment could then be used with confidence to characterize any anomalies in real tissue samples, and allow research findings to be accurately evaluated.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
490585-2015
Name nom
Sinclair, Anthony
Department département
Mechanical and Industrial Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
24950
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
513
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Electrical and electronic machinery and equipment (including computer hardware)
Area of application fr
Machinerie et équipement électriques et électroniques (y compris matériel informatique)
Research subject code
2001
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials structure, properties and testing
Research subject fr
Structure, propriétés et essais des matériaux
Partie
1
Nb partie
1
Application title
Ultrasonic phantom materials for equipment calibration
Keyword
NSERC
Application summary
Users of ultrasonic scanning systems for high frequency biomedical research require ""phantoms"" made of tissue-mimicking materials in order to calibrate the ultrasonic signals and understand the images acquired by the equipment. Without such phantoms, it is not practical to compare experimental results from different laboratories, or to transfer research findings to a clinical setting. Our objective in this project is to develop a new stable phantom material that has a similar response to ultrasound to that of human tissue at frequencies up to 50 MHz. Once this tissue-mimicking material has been developed, it can also be used by our industrial partner FujiFilmVisualSonics to assemble more complex phantoms that can be used for technician training or interpretation of ultrasonic images. The key challenge in this project is to attain appropriate levels of ultrasonic velocity, attenuation, and density to mimic human tissue - all within a single, stable material. By adjusting the amount of cross-linking of polymer chains during the manufacturing response, we intend to adjust the ultrasonic damping to bring it in line with almost any specified biomedical tissue. A process to embed thin tungsten wire filaments and nylon fibers in straight lines inside the phantom material for equipment calibration purposes is also being developed; these targets will provide a suitable calibration test for equipment to confirm that its sensitivity and resolution meet required specifications. The VisualSonics equipment could then be used with confidence to characterize any anomalies in real tissue samples, and allow research findings to be accurately evaluated.