Fouling of finned-tube heat exchangers by aerosols: impact on HVAC design

EF 2013-14

Résumé
Finned tubes are used in most air-to-liquid heat exchangers, including those used in building heating andventilation systems. It is well known that over time these fins and tubes become fouled by airborne particulatematter. It is also well known that the systems must be cleaned periodically to maintain good performance, butit is not known how frequently this should be done to save money, energy and maintain good indoor air quality.These factors depend on the heat exchanger design, ambient conditions, and how it is built into a ventilationsystem (for example, the type of filters upstream of the heat exchanger, the desired air flow rate, and othervariables). The proposed research will provide the experimental data and phenomenological models needed toproperly design and specify heat exchanger filtration and cleaning for particular applications.An apparatus has been designed to study how the geometry of finned-tube coils (tube diameter, row number,fin thickness, fin density, and fin shape) and operating conditions (face velocity, relative humidity, airtemperature, coil wall temperature, air particulate concentration, etc.) affect the accumulation of airborneparticulate matter in the heating and cooling coils of a fan coil unit. UBC will obtain from Cancoil specificfinned-coil tubes to carry out this research. The proposed research will help Cancoil refined design procedures,and will help building operators reduce life-cycle system costs.
Programme
Engage Grants Program
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
452486-2013
Name nom
Rogak, Steven
Department département
Mechanical Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
23750
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
1
Nb partie
1
Application title
Fouling of finned-tube heat exchangers by aerosols: impact on HVAC design
Keyword
NSERC
Application summary
Finned tubes are used in most air-to-liquid heat exchangers, including those used in building heating andventilation systems. It is well known that over time these fins and tubes become fouled by airborne particulatematter. It is also well known that the systems must be cleaned periodically to maintain good performance, butit is not known how frequently this should be done to save money, energy and maintain good indoor air quality.These factors depend on the heat exchanger design, ambient conditions, and how it is built into a ventilationsystem (for example, the type of filters upstream of the heat exchanger, the desired air flow rate, and othervariables). The proposed research will provide the experimental data and phenomenological models needed toproperly design and specify heat exchanger filtration and cleaning for particular applications.An apparatus has been designed to study how the geometry of finned-tube coils (tube diameter, row number,fin thickness, fin density, and fin shape) and operating conditions (face velocity, relative humidity, airtemperature, coil wall temperature, air particulate concentration, etc.) affect the accumulation of airborneparticulate matter in the heating and cooling coils of a fan coil unit. UBC will obtain from Cancoil specificfinned-coil tubes to carry out this research. The proposed research will help Cancoil refined design procedures,and will help building operators reduce life-cycle system costs.