Upgrade of a time-resolved particle image velocimetry system

EF 2024-25

Résumé
Hydroelectricity is the key renewable energy source for Canada's energy transition. The Heki Hydroelectricity Innovation Center at Université Laval is Canada's only independent research center equipped with a test stand specializing in R&D on hydraulic turbines. It focuses on providing a better understanding of the hydrodynamic and structural behaviour of hydraulic turbines. Heki partners are leading manufacturers of hydraulic turbines, Andritz Hydro, GE Vernova, Voith Hydro, electricity producers, Hydro-Québec, EDF (France) and Vattenfall (Sweden), and researchers from Polytechnique Montréal, École de Technologie Supérieure, Polytechnical University of Catalonia. The consortium is launching a five-year program to study operational anomalies in Francis turbines, the most common in Canada. The project will provide the R&D departments of the participating industrial partners with knowledge, tools and methods to enhance turbine design and operation, boosting flexibility and supporting renewable energy integration (wind and solar) into the grid. The primary measurement tool at Heki, for past, present and future projects, is a Time-Resolved Particle Image Velocimetry (TR-PIV) system, which captures velocity fields within a flow to analyze its behavior. The time-resolved capability enables the system to record velocity fields at high speeds, in the order of 1000 fields per second, allowing us to examine rapid flow variations. For instance, we can track the temporal evolution of large vortices that cause turbine vibrations. Our TR-PIV system is also being used by Prof. Ruel and Maciel in a project on the biofabrication of tissue-engineered heart valves, in collaboration with Université Laval's Tissue Engineering Laboratory (LOEX). The system enables the characterization of the flow through the fabricated valves in a cardiac flow simulator, helping to assess the risk of long-term complications. The goal of this proposal is to replace a critical, outdated, and malfunctioning component of our TR-PIV system: the high-repetition-rate laser that generates light pulses at up to 10,000 pulses per second. Simply put, the PIV method measures flow velocity vectors by tracking the displacement of tracer particles between two consecutive images. The laser provides the light sheet to brightly illuminate the particles. Our current laser, now 11 years old, has been malfunctioning for the past few years and is beyond repair. The successful completion of our research projects now strongly depends on acquiring a new, more reliable laser.
Programme
Research Tools and Instruments
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RTI-2025-00164
Name nom
Maciel, Yvan
Department département
Génie mécanique
Organization id
51
Institution établissement
Université Laval
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2025
Award amount
150000
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1612
Committee name en
Mechanical Engineering (RTI)
Committee name fr
Génie mecanique (OIR)
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
2105
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Hydraulics
Research subject fr
Hydraulique
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Upgrade of a time-resolved particle image velocimetry system
Keywords
hydraulic turbine; hydrodynamics; flow measurements; particle image velocimetry; high-repetition-rate laser
Application summary
Hydroelectricity is the key renewable energy source for Canada's energy transition. The Heki Hydroelectricity Innovation Center at Université Laval is Canada's only independent research center equipped with a test stand specializing in R&D on hydraulic turbines. It focuses on providing a better understanding of the hydrodynamic and structural behaviour of hydraulic turbines. Heki partners are leading manufacturers of hydraulic turbines, Andritz Hydro, GE Vernova, Voith Hydro, electricity producers, Hydro-Québec, EDF (France) and Vattenfall (Sweden), and researchers from Polytechnique Montréal, École de Technologie Supérieure, Polytechnical University of Catalonia. The consortium is launching a five-year program to study operational anomalies in Francis turbines, the most common in Canada. The project will provide the R&D departments of the participating industrial partners with knowledge, tools and methods to enhance turbine design and operation, boosting flexibility and supporting renewable energy integration (wind and solar) into the grid. The primary measurement tool at Heki, for past, present and future projects, is a Time-Resolved Particle Image Velocimetry (TR-PIV) system, which captures velocity fields within a flow to analyze its behavior. The time-resolved capability enables the system to record velocity fields at high speeds, in the order of 1000 fields per second, allowing us to examine rapid flow variations. For instance, we can track the temporal evolution of large vortices that cause turbine vibrations. Our TR-PIV system is also being used by Prof. Ruel and Maciel in a project on the biofabrication of tissue-engineered heart valves, in collaboration with Université Laval's Tissue Engineering Laboratory (LOEX). The system enables the characterization of the flow through the fabricated valves in a cardiac flow simulator, helping to assess the risk of long-term complications. The goal of this proposal is to replace a critical, outdated, and malfunctioning component of our TR-PIV system: the high-repetition-rate laser that generates light pulses at up to 10,000 pulses per second. Simply put, the PIV method measures flow velocity vectors by tracking the displacement of tracer particles between two consecutive images. The laser provides the light sheet to brightly illuminate the particles. Our current laser, now 11 years old, has been malfunctioning for the past few years and is beyond repair. The successful completion of our research projects now strongly depends on acquiring a new, more reliable laser.